GMG-K / GMG-L Operation manual
Page 34 of 58
B0793 / B0796
Machine pulses ON / Lower row time OFF / Upper row distributor pulses OFF variant
(For flow diagram see sub-section 11.2.10)
(Precondition: Monitored progressive distributor in the upper row of elements,
control C/C3)
In this setting, the lower element row of the pump unit is switched on for a particular duration
(delivery time) when a particular number of machine pulses is available, whilst the upper
element row will be switched on within a particular number of machine pulses for a particular
number of pulses from the monitored progressive distributor.
For both the lower and upper row of elements, different numbers for the machine pulses,
delivery times, and pulses from the progressive distributors can be set. In case of an
overlapping delivery between the lower and upper element rows, the running delivery will be
stopped first. Then, switch-over to the other row will be made.
The distributor monitoring P17 will be switched on in this mode automatically (when P15 is
reset to 1).
P17 will not be reset automatically.
When changing the mode or resetting P15 to 0, the status of P17 needs
to checked and reset manually, if necessary!
Machine pulses ON / Lower row distributor pulses OFF / Upper row time OFF variant
(For flow diagram see sub-section 11.3.11)
(Precondition: Monitored progressive distributor in the lower row of elements,
control C3)
In this setting, the lower element row of the pump unit will be switched on within a particular
number of machine pulses for a particular number of pulses from the monitored progressive
distributor, whilst the upper row of elements will be switched on within a particular number of
machine pulses for a particular duration (delivery time).
For both the lower and upper row of elements, different numbers for the machine pulses,
delivery times, and pulses from the progressive distributors can be set. In case of an
overlapping delivery between the lower and upper element rows, the running delivery will be
stopped first. Then, switch-over to the other row will be made.
The distributor monitoring P7 will be switched on in this mode automatically (when P5 is set
to 1).
P7 will not be reset automatically.
When changing the mode or resetting P5 to 0, the status of P7 needs to
checked and reset manually, if necessary.