Assembly
33
Pneumatic circuit diagram
Pneumatic circuit diagram
When controlling the quick-change pallet system, the following
must be observed:
Turbo function:
• The actuating pressure for the turbo function must not exceed
6 bar.
Feeder query:
• The max. pressure of the feeder query is 2 bar.
• Limit volumetric flow to 15 l/min.
• Pressure difference upon failure of a module min. 1 bar.
• If the feeder query of several standard modules is connected
in series, only the evaluation of the OPEN position works
(dynamic pressure = all modules open).
4.7