The clamping area does not unlock
Possible cause
Remedial measures
Defective air connections
Check air supply
Pressure below minimum
Check operating pressure (min. 5 bar)
A component is broken
(e.g. due to overloading)
Replace the module or send it to WNT for
repair
Excess tensile load on clamping pins
Reduce support weight
The clamping area does not unlock properly
Possible cause
Remedial measures
Pressure below minimum
Check operating pressure (min. 5 bar)
The module was not operated with oiled
compressed air
Install maintenance unit with oiler
Hose diameter below minimum
Required hose diameters, see chapter
The turbo connection is still pressurized Ventilate the connection
The quick-change pallet system no longer opens quietly
Possible cause
Remedial measures
The clamping faces on the clamping slides
and on the clamping pin are dirty
Remove the clamping pin and clean the
clamping faces on the clamping slides and on
the clamping pin