Assembly
34
Air purge/contact monitoring (optional):
• Max. pressure 2 bar.
• Limit volumetric flow to 15 l/min.
Exhaust air (optional):
• Max. pressure 6 bar.
• The exhaust air must be switched off before the modules are
locked, as otherwise an air cushion may form.
In order to guarantee reliable evaluation, the pressure and air
volume must be held constant. Pressure fluctuations can affect the
settings of the pressure switch and lead to incorrect measurement
results. The length and cross-section of the line can affect the
switching time of the control components. It may be necessary to
readjust the control components. Check the control components
of the monitoring functions at regular intervals. If errors occur in
the monitoring control system, you must detect the cause of the
error.
Screw tightening torques
Tightening torques for mounting clamping pins
(Screw quality 12.9)
Screw size
M6
M8
M10
M12
M14
M16
Tightening torque (Nm)
15
32
62
108
170
262
Tightening torques for mounting the modules
(Screw quality 10.9)
Screw size
M4
M5
M6
M8
M10 M12 M14
Tightening torque (Nm)
4.2
7.5
13
28
50
88
120
4.8
Содержание 80 809 070
Страница 1: ...Original Betriebsanleitung WNT Nullpunktspannsystem PNG PNG SST Montage und Betriebsanleitung...
Страница 29: ...Montage 29 PNG SST 6...
Страница 40: ...Zusammenbauzeichnungen 40 Zusammenbauzeichnungen PNG 138 PNG T 138 9 9 1...
Страница 41: ...Zusammenbauzeichnungen 41 PNG V 138 9 2...
Страница 71: ...Assembly 29 PNG SST 6...
Страница 82: ...Assembly Drawings 40 Assembly Drawings PNG 138 PNG T 138 9 9 1...
Страница 83: ...Assembly Drawings 41 PNG V 138 9 2...