Important!
The module and the SIM card uses the PIN code specified in the "
Mobile network
"
parameter group when connecting.
5.
If the modem restarts due to an incorrect configuration, it is possible to access it with a CSD
call. Its operation can be fine-tuned by setting the
PDP Connection Delay
value. There you
can add a delay (value in minutes)
–
the parameter can be set between 3 and 255). The
handle of the PDP feature is the following:
•
If the modem needs to be restarted for the 1st time because it could not connect to the
network and did not receive an IP address, there is no change, there will be no extra delay
added.
•
If the modem has been restarted for 2nd time because you have not received an IP
address, then the device will wait 1 minute more before the restart to allow more time to
connect through the CSD.
•
If the modem has been restarted for 3rd time because you have not received an IP
address, the device will wait 2 minutes before restart to allow even more time to connect
to the CSD.
•
If the modem has been restarted for 4th time because you still have not received an IP
address, the device will wait for the amount of time you have specified at the PDP
Connection Delay parameter to allow more time for the CSD to connect before restart.
•
If the modem has been restarted for 5th time because you have not received an IP
address, the cycle will start over and the modem will not wait to restart… (according to
the step nr. 1)
6.
Push the
OK
button and continue with the next part.
5.2 Wireless settings
1.
Choose the
M2M
parameter group for the cellular communication settings (2G, 3G, 4G, Cat.M,
Cat.NB, etc).
2.
Push the
Edit valu
es button, and the relevant parameters and their values will be
listed.