background image

 
 

The  modem  is  thus  suitable  for  transmitting  the  incoming  data  of  the  connected  device 

transparently through the wireless network. 
 

Power source and power outage 

The  device  can  be  powered 

from  the  meter’s

  mains  connection  (by  general  100V-240V  AC 

voltage). 

The modem can be connected through the following modes: 

a.)

 

the  meter  is  connected  to  the  57.7/100V  AC  power  network:  the  modem  must  be 

connected to phase voltage (100V, L1..L2 or L2..L3 or L1..L3) 

b.)

 

the meter is connected to the 230/400V AC power network: the modem must be connected 
to the line voltage (230V, L1..N or L2..N or L3..N) 

In case of the need of using external DC power, the modem can be orderd in DC-voltage version. 

 
Configuration and firmware refresh 

The modem can be configured locally via RS232 port, remotely with a CSData call (only if you 

use a setting that also uses a 2G network!) Or via a mobile internet (TCP) connection, and its 
firmware  can  be  updated.  The  modem  is 
configurable  via  TCP  port  remotely  (or  via  local 

serial  connection)  and  operating  on  the  wireless 
network  by  configuring  the  APN,  username  and 
password (APN information is provided by your local 
mobile operator).  

All  settings  can  be  configured  with  our 
administration tool (the WM-E Term

®

 software), but 

also API available so our partner can easily adapt their current administration environment. 
The configuration is possible by one device or for a group of devices. 
The WM-E Term

®

 tool is password protected and user management is also possible.  

The configuration tool requires Windows

®

 platform to run. It is available in English and some 

local languages as well (as French, Spanish, Czech, etc.). 

 

Certification 

The modem is accomplishing with CE standard (Radio Equipment Directive (2014/53/EU)) and 
safety directives (EN 60950-1) and RoHS declaration and has CE certification. 

 

 

Содержание Universal Industrial RS485 Modem

Страница 1: ...User manual for Universal Industrial RS485 Modem ______________________________________________ Rev 2 70 2020 05 11...

Страница 2: ...ration steps of the Universal Industrial RS485 modem Document Version REV 2 70 Hardware Type Version Universal Industrial RS485 modem Hardware Version V 4 60 Firmware Version V 2 4 25 7 WM E Term conf...

Страница 3: ...m 12 4 3 Setup the connection 14 4 4 Connect to the modem 16 4 5 Choose a parameter group 18 4 6 Modify the settiongs 20 Chapter 5 Parameter settings 22 5 1 APN settings 22 5 2 Wireless settings 23 5...

Страница 4: ...Read 40 6 8 User management 41 6 9 Event log 42 6 10 Check modem communication 43 6 11 Ping host 43 6 12 AT commands 44 6 13 Print 45 6 14 General settings 45 6 15 Password change 46 6 16 Configuring...

Страница 5: ...s the modem can initiate the communication with the AMR centre periodically at a pre programmed time interval or triggered by an alarm power outage cover removal reverse run etc The modem can be confi...

Страница 6: ...f you use a setting that also uses a 2G network Or via a mobile internet TCP connection and its firmware can be updated The modem is configurable via TCP port remotely or via local serial connection a...

Страница 7: ...for the AC power of the meter 2 RS232 connector DSUB9 optional 3 RS485 connector 2 pin or 4 pin order option wire with sleeve 4 Antenna connector SMA M 50 Ohm 5 SIM card slot push insert 6 Status LED...

Страница 8: ...nt external magnetic base antenna 12 corresponding to the communication to the antenna connector 4 Step 4 Connect the modem to your computer with the RS232 cable 2 and an RS232 USB converter for the c...

Страница 9: ...also indicated by LED flashes You can now set the modem parameters Then the modem will be power supplied by the meter and the modem will start its operation and the LED signals are signing the current...

Страница 10: ...correct the LED flashes every 1 second If there is no SIM the LED flashes every 1 second RSSI flashes the LED according to the field strength value 1 flash lasts for 1 second followed by a pause o RSS...

Страница 11: ...seconds and then all three light up The modem will then restart and use the new firmware Then each LED will continue to flash according to the listed states 3 4 RS485 connector pinout 3 5 Configuring...

Страница 12: ...figuration to the modem 4 2 Configuring the modem by WM E Term 1 The configuration software can be used on Microsoft Windows 7 8 10 operating systems 2 Microsoft Net Framework v4 must be installed on...

Страница 13: ...7 Enter the login data to enter into the configuration software Default Username Admin Default Password 12345678 8 Select the WM E1S modem type and push the Select button there...

Страница 14: ...he communication At the bottom of the screen on the lef hand side you can connect with a pre configured profile to the modem by selection 4 3 Setup the connection 1 Make serial RS232 connection betwee...

Страница 15: ...aud rate during the firmware by enabling the Switch enable option and choosing a baud rate from the list This will be valid for the fw update period 7 When you have finished click on the Save button t...

Страница 16: ...escribed at the serial connection 5 Define the IP address o the connected SIM card and the Port for the connection 6 Push then the Save button to save the profile settings 4 4 Connect to the modem You...

Страница 17: ...igured settings will be loaded from the modem to the WM E Term software The progress will be signed by the indicator bar on the righ bottom side of the screen After loading the parameters at the top o...

Страница 18: ...oose another Parameter group by its button The available parameter groups depend on the currently used metering modem model and the used firmware Choosable parameter groups AMM IEC NOT AVAILABLE FOR T...

Страница 19: ...T AVAILABLE FOR THIS MODEM Device Manager optional for configuring the Device Manager server connection for monitoring and maintaining the modems remotely M Bus NOT AVAILABLE FOR THIS MODEM P1 Custome...

Страница 20: ...up you have to push the Edit values button again When you have modified the required parameters push the OK button to record the settings Note that the settings will NOT be saved automatically or sent...

Страница 21: ...r the parameter writing sending the modem will be disconnected and it will be rebooting then operating according to the new settings Until the end of the restart process and the proper operation statu...

Страница 22: ...arameters and their values will be listed 3 At the bottom side of the screen fill in the following fields APN Name here you have to add the APN zone name according to the modem SIM card ask your Mobil...

Страница 23: ...efore the restart to allow more time to connect through the CSD If the modem has been restarted for 3rd time because you have not received an IP address the device will wait 2 minutes before restart t...

Страница 24: ...MM SS 4 Encryption password via MD5 algorithm You can ask for encryption of the password via MD5 algorithm Values 0 false 1 true 5 Additional delay time interval in case of using push to give some del...

Страница 25: ...he Waiting time until next try field is not implemented yet 13 Push the OK button and continue with the next part 5 3 Mobile network settings 1 Choose the Mobile network parameter group for editing th...

Страница 26: ...the main channel e g to the LTE Attention In case of using a 4G modem if you have selected the All available access technology and despite of the selection the module still not access the 4G network c...

Страница 27: ...nfigurable Manual reboot caused by any configuration modification Auto reboot will run periodically based on a configurable timer which can be set up to 24 hours configurable and can be scheduled The...

Страница 28: ...device add the HHMM value of the time of the device restart Leave it empty if you do not allow the device to restart every day 6 GPRS connection closed and restored after this time sec If ping is conf...

Страница 29: ...the number of remote firmware upgrade retries in case of FOTA progress 10 At the Status of the update process you can get a message for the device s FOTA status 11 If you want to reboot the device ena...

Страница 30: ...Push the OK button and continue with the next part 5 6 Device Manager settings The Device Manager is an optional remote management software order option which can be used to maintain and to monitore t...

Страница 31: ...uence of the settings in the Device Manager manual ask our sales department 5 Push the OK button and continue with the next part The further certification and security fields cannot be selected for th...

Страница 32: ......

Страница 33: ...re version as identifiers are listed The current connection settings are listed here as modem and firmware indentifiers cellular network provider code and operator name available network and access te...

Страница 34: ...ved and prepared configuration you can open it from the File menu by the Open item 2 Browse the required configuration file with CFG extension and push the Open button 3 The program will then load the...

Страница 35: ...devices You can use this feature for the quick parameter configuration of multiple modems 1 Choose the Tools Mass Configuration item from the menu 2 Push the Browse button to select a mass configurat...

Страница 36: ...od will be shown at the progress bar Attention Please be careful The modem has several firmware types Therefore always ask our sales team about the proper firmware version Please note when updating th...

Страница 37: ...select the DWL extension firmware file 3 Push the Start firmware update button for performing the singular firmware upload 4 The progress of upload will be shown at the right bottom progress indicato...

Страница 38: ...directory settings before 3 Then the requested mass fw update list is loaded and the WM E Term will searching for the dwl extension files in the declared directory based on the CSV file of the list o...

Страница 39: ...ry channel for CSD to the modem then click the Try modem option and define the Telephone number of the module About the CSV file you can see an example here SMP_WME1S_V2_4_25_7 dwl V2 4 19 172 31 154...

Страница 40: ...rsion 11 At the end of the refresh process the modems will restart and will use the updated firmware version Attention The new firmware will be available only after the firmware upload process whe it...

Страница 41: ...6 8 User Management 1 Choose the Admin menu Manage users menu item...

Страница 42: ...art when you will attempt to login 6 9 Event log You can check the events of operation and modem interaction communication by the Event log item 1 Open the icon for listing the previously recorded log...

Страница 43: ...ssage types by the Type filter and Thread filter field options by selecting the required items The Log Folder and Open buttons help you open the stored previous log files to analyze By choosing the Co...

Страница 44: ...6 12 AT commands Select the AT interface tab on the left side of the screen...

Страница 45: ...arameter settings of the modem After choosing the log period by selecting the Log icon and a logged interval push the icon from the menu or choose File Print item from the menu The print view of the p...

Страница 46: ...an define the path directory for the configuration files firmware log Save your settings when you have modified the configuration Important The program will store the changed settings and when you sta...

Страница 47: ...o the Confirm communication password Note that the written passwords are substituted by asterixes for security reasons 3 Push the Change button for performing the password change 6 16 Configuration of...

Страница 48: ...ings 3 Save your settings by pushing the OK button You will need to push then the Parameter write icon to send it to the modem Important Please note when embarking on the LED configuration that the WM...

Страница 49: ...roduct has identification void which has important product related information for the support line Warning Damaging or removing the void sticker means the loss of product guarantee Online product sup...

Страница 50: ...res in this document are illustrations those can be different from the real appearance The WM Systems LLC doesn t take any responsibility for text inaccuracy in this document The presented information...

Страница 51: ...wireless voice telephony mobile Internet access The following common standards comply with the 3G standard UMTS system first offered in 2001 standardized by 3GPP used primarily in Europe Japan China h...

Страница 52: ...d timing of signals the meaning of signals and the physical size and pinout of connectors RS485 RS 485 is a standard defining the electrical characteristics of drivers and receivers for use in serial...

Отзывы: