7.
Here you can define the
Port for the transparent
(IEC) meter readout
–
for the port
number of the communication with the external measurement device.
8.
To define a different
Port for downloading
the config and firmware refresh.
9.
The
AES-256 CBC encryption
option is inactive.
10.
You can also configure the
Number of GPRS connection
attempts
until module reset
.
11.
There are presetend some refine settings to define as
Time between GPRS connection
attempts (in seconds)
- if the PDP context activation was not successfull, it will delay the
reconnection according to the listing.
12.
The
Waiting time until next try
field
–
is not implemented yet.
13.
Push the
OK
button and continue with the next part.
5.3 Mobile network settings
1.
Choose the
Mobile network
parameter group for editing the cellular connection parameters.
2.
Push the
Edit values
button, and the relevant parameters and their values will be listed.
3.
At the bottom side of the screen fill in the following fields:
-
SIM PIN code
–
check in the field if the SIM card that you are using needs a PIN code and
fill in the code here
- You can add a
Password for CSD call
- You can define the
Number of rings before accept call (CSD)
-
Cellular band
–
here you can define the mobile network and connection type (2G, 3G, 4G
LTE Cat.M/Cat.NB, and you can choose the option for the fallback* feature) for the modem
communication