Warning: To prevent airflow restriction, allow clearance around the ventilation openings to be
at least: 3 inches (7.6 cm). Statement 1076
Warning: Hot surface. Statement 1079
Caution: This industrial router can only be accessed by service personnel or by users who have
been instructed about the reasons for the restrictions applied to the location. Access is through
the use of a tool or lock and key, or other means of security, and is controlled by the authority
responsible for the location.
Caution: Be aware of the size and weight of the industrial Router when mounting. Ensure that
the mounting location has a stable flat surface and can safely support the weight of the device.
1.3
Mounting, fixation
The device enclosure (unit) contains a DIN-Rail fixation due its case, which is to be intended to
mount to DIN-35 rail or using a 3-point fixation by screws, or using the hook (in hanging
position).
You can also mount the enclosure to wall, place into server rack or similar fixation opportunity.
The unit must be mounted inside a cabinet by the listed fixation points, in vertical orientation.
Please note that close metal parts, the cabinet metal material and the industrial conditions as
the usage of high rate power or other external gained radio frequency signals can cause radio
signal disturbance and could cause weak wireless signal at reception or data transmitting or
could cause less effective signal reception, weak wireless fidelity. In any of these, we recommend
you to test the wireless signal reception and quality and if it is necessary use external, magnetic
mount antenna which is leaded outside of the cabinet and placed onto the cabinet’s surface –
to ensure enough reception.
Figure of bottom side of the unit enclosure
A – Device housing case back plate
B – Hook for fixation to wall/mount
C – DIN-rail sleede for fixation
D – DIN-rail position holder (release/fixate)
E – Additional hooks for fixation to wall/mount