Disturbances during operation and troubleshooting
25
Original-Betriebsanleitung
HD1+HD2
•HD1-2_BAoDB_en_1407•ski
Faults
Probable Causes
Remedies
5. Pump cycles unevenly and
does not reach the required
injection pressure. (The
uneven cycling of the pump
is recognizable by the diffe-
rence of the cycling speed of
the upward and downward
strokes)
➤
➤
The viscosity of the material
is too high (suction loss).
➤
Thin down material (add
solvent).
➤
Use bigger pump..
➤
➤
Suction system is not tight
(injection stream pulsates).
➤
➤
Check all seals on fittings of
the suction pipe and hose
and exchange if necessary.
➤
➤
Bottom valve is leaking
(pump only stops on the
upward stroke when the
injection gun / lance is
closed).
➤
➤
Unscrew bottom valve.
Thoroughly clean ball
with seat or exchange if
necessary.
➤
➤
Piston valve is leaking (pump
only stops on the downward
stroke when the injection
lance is closed).
➤
➤
Check and clean ball with
seat of the dual piston or
exchange if necessary
➤
➤
Upper or lower packing is
worn.
➤
➤
Exchange packings.