Translation of the original operation manual
HERKULES PFP
35
HERKULES PFP_BAoDB_en_1402_B · rs
Maintenance
3.
Check whether there is enough lubricant – when filled completely, the
lubricant reaches to a point approx. 2 cm below the upper edge of the oil
reservoir.
4.
Top up lubricant, if necessary.
We recommend using pneumatic oil (order number 0632579) or antifreeze
(order number 0631387) from WIWA.
5.
Reattach the oil reservoir to the air maintenance unit.
6.3.2 Checking and adjusting the fog oiler
1.
Let the main pump run slowly under load.
2.
Check in the fog oiler inspection glass whether 1 drop of lubricant is fed
after each 10 to 15 double strokes of the air motor.
3.
If this is not the case, adjust the metering by turning the regulating screw
on the fog oiler with a screwdriver.
6.3.3 Checking and cleaning the water separator
The water separator prevents condensation water and dirt particles from enter-
ing into the unit. In addition, a filter is installed in the water separator, which fil
-
ters out particles > 40 μ from the compressed air. Therefore, no static charging
of the pneumatic hoses is to be expected.
The accumulated condensation water is automatically drained off through the
drain valve. For this purpose hold the hose into an empty collecting vessel.
Check the bowl regularly for dirt residues and clean it as required.
6.4 Fluid pump
Fig. 26: Fluid pump
2
3
1
No. Designation
1
Release agent
filler pipe
2
Inspection glass
3
Release agent
drain screw
6.4.1 Checking the release agent level
Check the amount of release agent before every start-up. The release agent
level must be at least half the inspection glass. If required, top up the amount of
release agent through the filler pipe. We recommend using release agent from
WIWA (order number 0163333).