22
Translation of the original operation manual
HERKULES PFP
HERKULES PFP_BAoDB_en_1402_B · rs
Transportation, installation and assembly
4.3.1 Open the ventilation hole
When being used for the first time,
the sticker with the text „remove be
-
fore use“ and the sealing plug is to be
removed from the ventilation hole.
The ventilation hole is located in the
elbow with the openeing facing down-
ward (overflow).
Fig. 8: Ventilation hole
4.3.2 Assembling spray hose and spray gun
Fit the spray hose to the material out-
let of the fluid pump (see Fig. 9).
Connect the spray hose to the spray
gun as described in the operating
manual for the spray gun.
Fig. 9: Connection for the spray hose
4.3.3 Grounding the unit
WARNING
The high flow velocities associated with the Airless spraying method may
cause electrostatic charging. Static discharges can cause fire and explosion.
➤
Make sure that the unit and the object to be coated are properly grounded!
The grounding cables for all compo-
nents for which grounding is required
are merged into the grounding termi-
nal.
In order to ground the unit, connect
the main grounding cable first to
clamp 1 of the grounding terminal
and then to an electrically conductive
object outside the hazardous area.
Fig. 10: Grounding terminal
Содержание HERKULES PFP
Страница 2: ......
Страница 39: ...Translation of the original operation manual HERKULES PFP 39 HERKULES PFP_BAoDB_en_1402_B rs...