5.4 Installation space
The drive amplifier is designed for installation in a control cabinet or closed installation space.
5.5 Environmental conditions for vibration/shock
The drive amplifier fulfills the following specifications:
−
Vibration according to DIN EN 60068-2-6:2008
o
Frequency range 10 Hz – 150 Hz
o
Acceleration: 5 g
−
Shock according to DIN EN 60068-2-27:2010
o
Shock form: Semi-sinusoidal
o
Acceleration: 50 g
o
Duration of the shock: 11 ms
5.6 Mounting position
The drive amplifier can be installed in any mounting position.
A vertical mounting position with a cooling unit should be used to achieve optimum heat
dissipation.
Performance will decrease if the drive amplifier is not in vertical mounting position, or if the
converter is used with insufficient cooling.
A minimum distance must be ensured if several drive amplifiers are mounted side by side.
Please consult the Application department of Wittenstein cyber motor GmbH regarding the
design of the heat dissipation concept.
5.7 Heat dissipation
The SIM2050D cooling unit should be used for heat dissipation. It is available as an accessory.
Only this cooling unit and a proper mounting position will ensure that the nominal continuous
current of the output stage can be reached and that the device will not overheat.
Other types of heat dissipation can be coordinated with the Application department of
WITTENSTEIN cyber motor GmbH.