simco
®
drive SIM2050
Operating Manual
en-22
4022- D048047
Revision: 04
6.7.8 X8: Power supply
−
The logic supply is galvanically isolated from the intermediate voltage.
−
The safety input STO is galvanically isolated from the intermediate voltage.
Figure
Pin
no.
Signal name Function
Input/
output
1
VCC24
Logic 24 VDC Input
2
STO
Safe Torque off input
Input
3
GND
Logic reference
ground
Input
4
STO GND
STO
reference ground
Input
5
BRAKE+
Holding brake +
Output
6
BRAKE-
Holding brake -
Output
7
Motor temperature
Input
8
TempMot-
Motor temperature
sensor -
Input
9
External temperature
Input
10
TempExt-
External
Temperature-
sensor -
Input
Plug type on cable: TFMC 1.5/10-STF-3.5
Permissible wire cross-section: 0.25 .. 1.5 mm²
Stripping length: 10 mm
Connection
Properties
Unit
Minimum
value
Nominal
value
Maximum
value
VCC24
Voltage
V DC
12
24
60
Current @ 12V mA DC
500
Current @ 24V mA DC
220
Current @ 60V mA DC
100
STO
Voltage
V DC
12
24
60
Current
mA DC
120
BRAKE+/-
Voltage
V DC
24
Current
A DC
1,3
6.8 Fuses
•
The power supplies are to be secured with the fuses specified in the table:
Fuses
Logic supply (F2)
X8 (pin 1 + 2)
Fuse or similar with max. 4 AT
Power supply (F1)
X7 (pin 1)
Fuse or similar with max. 50 AT
Содержание Simco SIM2050D
Страница 1: ...4022 D048047 Revision 04 simco drive SIM2050D Operating Manual ...
Страница 2: ......