2.6 Intended use
The drive amplifiers are intended for operation of permanent magnet EC synchronous servo
motors with compatible feedback systems in stationary machines and systems.
Other uses must first be approved by the manufacturer.
Installation of the drive amplifiers is only approved in stationary electrical cabinets or
stationary machine frames. They are used in industrial environments. For use in residential
areas, additional EMC measures are necessary. The user must prepare a hazard analysis
of the final product.
2.7 Improper use
The drive amplifiers are not suitable for operation of motors other than EC synchronous
servo motors or motors with non-compatible feedback systems.
In addition, the following applications are excepted from intended use:
−
Life-sustaining medical devices
−
Applications in explosive areas
−
Use in nuclear plants
−
Use in airplanes
2.8 Risks
The manufacturer must strive to reduce residual risks associated with the drive amplifier as
much as possible by taking appropriate action. Nonetheless, known residual risks must be
taken into account for the risk assessment of machines and systems.
2.8.1 Prohibited movements
Prohibited movements can be caused by:
−
The failure or shut-down of safety monitoring
−
Software fault in associated controllers or bus systems
−
Error during parameterization
−
Wiring fault
−
Limited reaction time of the controller
−
Operation outside of the specifications
−
Electromagnetic interference, lightning strike
−
Component failure
2.8.2 Dangerous temperatures
Dangerous temperatures on the surface of the device can be caused by:
−
Faulty installation
−
Incorrect installation site
−
Faulty electrical protection
−
Conductive pollution, condensation