5.5 Changing the lamp
(without opening the casing)
Risk of getting burned!
Never touch the searchlight during operation without
protection. The casing can reach 120 °C. In case of burns cool the injured area
immediately and seek medical help.
Risk of glare!
Never look into the arc during operation. This is dangerous for the
eyes. Never point the searchlight directly at anyone. Before switching on make
sure that nobody is near the searchlight.
The lamp can be exchanged without opening the casing. To do this, switch off the
appliance via the button (O); the LED on the PSUH SKS 575 goes out. Switch over the
lamp using the lamp change mechanism (6) and then press the start button (I) on the
PSUH SKS 575 again. The changed lamp ramps up slowly to the full light intensity.
5.6 Switching
off
Attention!
Switch off the searchlight only via the button (O). In order to avoid a
vacuum in the casing, wait until the searchlight has cooled down before closing
the ball valve.
6. Maintenance
6.1 Cleaning
Clean the front glass on the outside as needed. When doing so check the function of the
fixing clamps and inspect them for rust. Cleaning the inside of the searchlight is not
necessary. A coloured film develops on the mirror surface over time. This is harmless
and does not affect the light power.
Risk of glare!
Ensure that the searchlight cannot be switched on during
cleaning work.
Содержание SKS 575
Страница 1: ...OPERATING INSTRUCTIONS SUEZ CANAL SEARCHLIGHT SKS 575 230 V 50 60 Hz ...
Страница 11: ...50100935001_SKS 575 Ver2 Rev 02112012E An overview of the unit 11 Circuit diagram ...
Страница 21: ...50100935001_SKS 575 Ver2 Rev 02112012E Type Approval 21 10 Type Approval ...
Страница 22: ...50100935001_SKS 575 Ver2 Rev 02112012E Type Approval 22 ...
Страница 23: ...50100935001_SKS 575 Ver2 Rev 02112012E Type Approval 23 ...