background image

FUTURE FLOOD INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

LIGHT

FIXTURE

(+)LINE

BLACK

(-)COMMON WHITE

GROUND

GROUND

LOCATION

1. 

Secure the Future Flood to any 1/2” NPS hole in a metal 

plate coverplate, junction box or landscape post.  Plug all 

unused holes and seal threads with silicone.

2. 

The swivel arm on the Future Flood allows 150º of vertical 

aiming adjustment. 

3. 

Do not aim fixture to any object closer than 18 inches.

LAMP INSTALLATION

CAUTION: Prior to installing, check that the lamp is 

the correct ANSI type and wattage.  Observe lamp 

manufacturer’s recommendations on lamp operation, 

ballast type and burning positions.

1. 

Disconnect power.  Make sure fixture and lamp are cool 

enough to touch.

2. 

Remove screw from the door clip on the top of the fixture.  

Open fixture, swing door down on hinges.

3. 

Fully insert lamp into socket.

4. 

Before closing door, make sure frame gasket is properly 

seated all around the fixture.

5. 

Close door. Replace screw on door clip, if desired.

WIRING

Do not use any supply voltage other than those specified 

below:
 

FF35-FF150 HPS   

120V only

 

FFH50-70 MH 

 

120V only

 

FF42QT   

 

120V thru 277V*

  * No internal wiring changes needed for various voltages as 

the ballast is quad tap electronic.

1. 

Connect the black fixture lead to the (+) LINE supply lead.

2. 

Connect the white fixture lead to the (-) COMMON 

supply lead.

3. 

Connect the bare copper Ground wire from fixture to 

supply ground.

CLEANING & MAINTENANCE

 

CAUTION: Be sure fixture temperature is cool enough 

to touch.  Do not clean or maintain while fixture is 

energized.

1. 

Clean glass lens with non-abrasive glass cleaning solution.

2. 

As lamps age, light output diminishes. Mass relamping at 

regular intervals ensures full light output at the highest 

efficiency.

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required 

for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 

FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

 

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

Отзывы: