User Manual
3
5.2
Markings on packaging
Symbol
Description
Symbol
Description
Wirnet iFemtoCell
Type of equipment
QR code
Final product ID
Serial number of product
or
other marking
CE marking indicating that the product complies with current
European directives, or other marking depending on the country
Packaging ID
Identifier of packaging
Marking indicating that the product complies with RoHS directives
Software version
Version of embedded software
Do not dispose of with domestic waste
MAC ADDR
MAC address
Product must be installed on a non-flammable substrate (UL 94V0)
Refer to the installation instructions before powering up
6
Installation of Wirnet iFemtoCell
6.1
Mounting of the enclosure
The Wirnet iFemtoCell enclosure must be mounted on any concrete pedestal,
concrete wall or any non-flammable surface (UL94-V0).
It must not be mounted on a flammable surface.
The Wirnet iFemtoCell may be mounted on a wall using the two oblong holes.
Only two screws (not included) are needed, all mounting informations are mentioned on the following drawing:
6.2
Setting connections
Before setting all connections, ensure that the power supply is not connected to the
mains supply.
When the Wirnet iFemtoCell is installed, three configurations are possible regarding the technology used to access Internet:
Ethernet connection, requiring an Ethernet access through a dedicated RJ45 cable
Wi-Fi connection, requiring a Wi-Fi access point
3G/4G connection via USB dongle (optional) and an USIM subscription (not included)
The three configurations may be used in parallel. A typical example is the possibility to insure Ethernet backup by a 3G/4G link.
The required connections needed to operate the Wirnet iFemtoCell are listed below (see chapter 4 “Overview” for details of connectors):
Power supply
Ethernet cable (not included)
LoRa antenna
USB mass-storage key (not included)
3G/4G USB dongle (optional) and an USIM subscription (not included)
The Ethernet cable is not provided and must consist of two RJ45 T 568A (or 568B) plugs on each side.
KERLINK recommends using a cable with the following characteristics:
•
Category: 6A
•
Shielding: STP (U/FTP) or SSTP (S/FTP)
•
Section conductors: AWG26
•
External jacket: LSZH or PUR
•
Maximum length: 100 meters
•
Operating temperature range:-20°C to +55°C
In case of 3G/4G connection with USB dongle:
•
KERLINK recommends using a validated USB dongle (contact your reseller to have the list of validated USB dongles).
Alternative dongle may require additional drivers and firmware update to be used.
•
To optimize the radio performances, when possible, KERLINK strongly recommends dissociating the 3G/4G USB dongle
away from the enclosure and the LoRa antenna by using a 1 meter extension cable.
WARNING
WARNING
i
i