User Manual
7
The Wirnet iFemtoCell 868 is considered as a category 2 receiver according to the EN 300 220-1.
The Wirnet iFemtoCell 868 has CE marking.
In Europe, the Wirnet iFemtoCell 868 station must comply with the ERC 70-3 requirements regarding duty cycle and maximum EIRP. They are
summarized in the following table:
ERC 70-03 Band
Frequency (MHz)
Power
Duty cycle
h1.3
863-865
14dBm ERP
0,1%
h1.3
865-868
14dBm ERP
1%
h1.4
868-868,6
14dBm ERP
1%
h1.5
868,7-869,2
14dBm ERP
0,1%
h1.6
869,4-869,65
27dBm ERP
10%
h1.7
869,7-870
14dBm ERP
1%
h2
870-873
14dBm ERP
0,1%
h2.1
870-873
14dBm ERP
1%
Annex2/c
870-873
27dBm ERP
2,5%
The power supply of the Wirnet iFemtoCell 868 must be a limited power source.
•
If the LoRa antenna is changed, the output power must be adjusted to take into account the gain of the antenna to not
overrule the ERC 70-3 regulation.
•
Be careful, some countries in Europe may have specific frequency range, EIRP and duty cycles regulations. Check the
local regulations before installing and commissioning the Wirnet iFemtoCell 868.
•
For other countries, outside Europe, check the frequency range, the maximum EIRP and duty cycle allowed.
11.2
Wirnet iFemtoCell 915MHz
The Wirnet iFemtoCell 915
complies to:
IEC 60950-1:2005/A1:2009/A2:2013
UL 60950 -1 : 2007, Amendment A1:2011, Amendment A2:2014
CAN/CSA-C22.2 NO. 60950-1-07 / A1: 2011 / A2: 2014
The Wirnet iFemtoCell 915 complies to both FCC and IC regulations.
Applicable documents:
CFR 47 FCC Part 15:
o
FCC 47 CFR Part 15 : 2016 - Part 15- Radio frequency devices
o
FCC PART 15.247 - Operation within the bands 902–928 MHz, 2400–2483.5 MHz, and 5725–5850 MHz (frequency hopping and digitally
modulated)
FCC Part 15.207 conducted emissions on AC mains in the band 150kHz – 30MHz
FCC Part 15.247 intentional radiated emissions
FCC Part 15.215 Additional provisions to the general radiated emissions limitations
RSS 247:
o
RSP-100 Issue 11, January 2016 - Certification of Radio Apparatus
o
RSS-Gen – Issue 4, November 2014- General requirements and Information for the Certification of radio Apparatus
o
RSS-247 Issue 1, May 2015 - Digital Transmission Systems (DTSS), Frequency Hopping Systems (FHSS) and License-Exempt Local Area
Network (LE-LAN) Devices
The associated FCC and IC identifiers of the Wirnet iFemtoCell 915 are:
Model: Wirnet iFemtoCell 915
FCC ID: 2AFYS-KLK915WIFC
IC: 20637-KLK915WIFC
The power supply of the Wirnet iFemtoCell 915 must be a limited power source.
Any changes or modifications to this equipment not expressly by Kerlink may cause, interference and void the FCC
authorization to operate this equipment.
This device complies with Industry Canada’s license-exempt RSSs.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation of
the device.
i
i
i