background image

 

User Manual 

 

7

 

 

The Wirnet iFemtoCell 868 is considered as a category 2 receiver according to the EN 300 220-1. 
The Wirnet iFemtoCell 868 has CE marking. 

 
In  Europe, the  Wirnet iFemtoCell  868  station must comply with  the  ERC 70-3  requirements  regarding  duty cycle  and  maximum  EIRP. They  are 

summarized in the following table: 

 

ERC 70-03 Band 

Frequency (MHz) 

Power 

Duty cycle 

h1.3 

863-865 

14dBm ERP 

0,1% 

h1.3 

865-868 

14dBm ERP 

1% 

h1.4 

868-868,6 

14dBm ERP 

1% 

h1.5 

868,7-869,2 

14dBm ERP 

0,1% 

h1.6 

869,4-869,65 

27dBm ERP 

10% 

h1.7 

869,7-870 

14dBm ERP 

1% 

h2 

870-873 

14dBm ERP 

0,1% 

h2.1 

870-873 

14dBm ERP 

1% 

Annex2/c 

870-873 

27dBm ERP 

2,5% 

 

 

The power supply of the Wirnet iFemtoCell 868 must be a limited power source. 

 

 

 

If the LoRa antenna is changed, the output power must be adjusted to take into account the gain of the antenna to not 

overrule the ERC 70-3 regulation. 

 

Be careful, some countries in Europe may have specific frequency range, EIRP and duty cycles regulations. Check the 

local regulations before installing and commissioning the Wirnet iFemtoCell 868. 

 

For other countries, outside Europe, check the frequency range, the maximum EIRP and duty cycle allowed. 

11.2

 

Wirnet iFemtoCell 915MHz 

The Wirnet iFemtoCell 915 

 

complies to: 

 

IEC 60950-1:2005/A1:2009/A2:2013 

 

UL 60950 -1 : 2007, Amendment A1:2011, Amendment A2:2014 

 

CAN/CSA-C22.2 NO. 60950-1-07 / A1: 2011 / A2: 2014 

 
The Wirnet iFemtoCell 915 complies to both FCC and IC regulations. 

Applicable documents: 

 

CFR 47 FCC Part 15: 

o

 

FCC 47 CFR Part 15 : 2016 - Part 15- Radio frequency devices 

o

 

FCC PART 15.247 - Operation within the bands 902–928 MHz, 2400–2483.5 MHz, and 5725–5850 MHz (frequency hopping and digitally 
modulated) 

 

FCC Part 15.207 conducted emissions on AC mains in the band 150kHz – 30MHz 

 

FCC Part 15.247 intentional radiated emissions 

 

FCC Part 15.215 Additional provisions to the general radiated emissions limitations 

 

RSS 247: 

o

 

RSP-100 Issue 11, January 2016 - Certification of Radio Apparatus 

o

 

RSS-Gen – Issue 4, November 2014- General requirements and Information for the Certification of radio Apparatus 

o

 

RSS-247  Issue  1,  May  2015  -  Digital  Transmission  Systems  (DTSS),  Frequency  Hopping  Systems  (FHSS)  and  License-Exempt  Local  Area 
Network (LE-LAN) Devices 

 

The associated FCC and IC identifiers of the Wirnet iFemtoCell 915 are: 
 

Model: Wirnet iFemtoCell 915 
FCC ID: 2AFYS-KLK915WIFC 

IC: 20637-KLK915WIFC 
 

 

 

The power supply of the Wirnet iFemtoCell 915 must be a limited power source. 

 

Any changes or modifications to this equipment not expressly by Kerlink may cause, interference and void the FCC 
authorization to operate this equipment. 

 

This device complies with Industry Canada’s license-exempt RSSs. 

Operation is subject to the following two conditions: 

1. This device may not cause harmful interference, and 
2. This device must accept any interference received, including interference that may cause undesired operation of 

the device. 

 

Содержание iFemtoCell

Страница 1: ...il Please check the appropriate version for the dedicated country Contact your reseller if required The present document addresses all the above Wirnet iFemtoCell versions 2 Description of features He...

Страница 2: ...lkscreened Reset marking 5 RJ45 connector Ethernet 13 Reset push button 6 3 bicolor LEDs 14 LoRa antenna 862 873MHz 902 928MHZ 3dBi 50 vertical polarization 7 Wall mounting oblong holes 15 AC power su...

Страница 3: ...garding the technology used to access Internet Ethernet connection requiring an Ethernet access through a dedicated RJ45 cable Wi Fi connection requiring a Wi Fi access point 3G 4G connection via USB...

Страница 4: ...cative software provided by KERLINK is installed RED if applicative software is disconnected GREEN blinking during applicative software connection GREEN fix if applicative software is connected LED 3...

Страница 5: ...ly is properly connected to the mains supply No LoRa data received The LoRa antenna is not well connected Check that a LoRa endpoint is within range of the Wirnet iFemtoCell Check the tightening of th...

Страница 6: ...pply output voltage 12 VDC Power consumption CPU module 20 load Ethernet link ON Wi Fi 25 Tx 75 Rx 3G 4G USB dongle HSPA 25 Tx 75 Rx Radio in Rx mode x8 demodulator on 1 3W max 0 5W max 1W max 1 6W ma...

Страница 7: ...1 2011 A2 2014 The Wirnet iFemtoCell 915 complies to both FCC and IC regulations Applicable documents CFR 47 FCC Part 15 o FCC 47 CFR Part 15 2016 Part 15 Radio frequency devices o FCC PART 15 247 Ope...

Страница 8: ...nditions 1 This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiator antenna and user s nearby person s body at all times 2 Thi...