2
017-
03
100
Configuration via Device Type Manager (DTM) and PACTware
6.4
Online and Offline Parameterization (PACTware)
The concept of online and offline parameterization applies only to configuration via device type
manager (DTM) with PACTware.
■
Offline Parameterization
(not connected to device)
If there is no active connection to the device, you can edit and save the data that is stored
locally in PACTware. You can transfer the local data to the device, as soon as a connection
to the device has been established.
■
Online Parameterization
(connected to device)
If there is an active connection to the device, you can directly edit the data that is stored
on the device. Parameter changes are immediately stored on the device.
Offline Parameterization
1. Right-click the device in the PACTware project view.
2. Choose
Parameter > Offline Parameterization
.
The window containing the offline data record appears.
3. Modify a parameter by typing in a new value or choosing a new value from the drop-down
list.
4. To accept the new value, press
Enter
.
5. After all parameter changes have been made, save your project by choosing
File > Save
.
6. To write the new offline configuration to the device, right-click the device in the project view
and choose
Connect
.
A connection to the device is established.
7. Right-click the device again and choose
Store to device
.
The new configuration is stored in the device.
Note!
Data that is edited and stored on the device during online parameterization is
not
automatically
synchronized with the offline data in the PACTware project. If you change device parameters in
online mode, the data in PACTware differs from the data on the device. To make sure the data in
PACTware matches the data on the device after online parameterization, load the data from the
device into the PACTware project.