4
)
Clean the bare part With
another alcohol tissue.
]
Check
:
After this operation,handle
the fiber so as not to damage
its bare glass.
]
Check:
Use
a
high-quality
alcohol,greater than 99%
pure.
]
Check: Change lint-free tissue or
gauze each time
(
5
)
Cleave the fiber with a fiber cleaver,Refer to page21
§
4.4.4
]
Note
:
Cleave length
:
16mm
。
]
Note
:
Do not clean the fiber after cleaving.
STEP3
:
Set the fiber in the splicer.
(
l
)
Gently set the stripped fiber in the V-groove.
]
Check
:
Set the fiber end-face between the V-groove tip and
electrode center line.
(
2
)
Gently close the sheath clamp.
(
3
)
Close the wind protector.
STEP4
:
Select Suited Splicer Mode
Press
<
>
into the setup program menu,
“
Select Program
”
be
selected suited splicer program of 3 column .Refer page 50
§
6.4
Select Program
STEP5
:
Splicing operation
Press
<
>
to start splicing. Refer to page 26
§
4.6
Splicing operation
STEP6
:
Fiber removal
(
1
)
Open the wind protector
(
2
)
Open the left and right sheath clamp
,
Remove the fiber.
Page 15
Fibe
Pass Fiber
Tension Member
Fiber protection sleeve
Fig.3-1
Pass Fiber
Full operation refer
right Fig.3-2
①
Clean Fiber
③
Remove Coating
④
Clean Bare glass
⑤
Cleaving Fiber
Bare Fiber
②
Pass Fiber
Fiber protection sleeve
Fiber melt sleeve
Tension Member
Coating
Fig.3-2
Fiber Stripping
Page 16