Shadow 8 User Manual
1139300
Troubleshooting
4-5
Other Troubleshooting Steps
Machine Run/Stop LED Is Red and No Fault Code Displayed
If the Machine Run/Stop LED is illuminated red even when you turn the Program/Run/Start
key switch to START, and the light curtains are unobstructed and no code is displayed on the
Main Receiver IBIs, disable both programmable fixed blanking and floating blanking, power
Shadow 8 down and then up, and realign the unit (see Checking Alignment, page 4-7).
In a multi-segment system, if the Machine Run/Stop LED on the Main Receiver is red, check
the alignment of all Extensions and realign if necessary. Alternately illuminated IBIs indicate
that the minimum number of consecutive beams for that pair of heads are not aligned (see
Table 2-13, page 2-50). Single illuminated IBIs indicate misaligned LED/phototransistor
pairs.
Machine Run/Stop LED Not Green
If the Machine Run/Stop LED on the Main Receiver is not illuminated green and there is no
object in the light field, dirt on the lens window may be blocking a light beam. Try cleaning
the lens window on both receiver and transmitter, referring to the instructions on page 4-7.
If, after cleaning the lens windows, the Machine Run/Stop LED is still not illuminated green,
the next step is to bring the optic heads to within 12 in. of each other. (Do not position the
heads closer than 12 in.) Unbolt either the receiver or transmitter, take the unbolted unit off
its mounting, and hold it directly in front of the other head. You may need to disconnect
wiring in order for the head to reach.
Make sure the lenses are pointed directly at one another and you have the Shadow 8 heads in
the same plane.
If the Machine Run/Stop LED is illuminated green after you have brought the heads close
together, there is a problem with your installation. Reread the mounting instructions starting
on page 2-15 to be sure you understand how Shadow 8 heads should be mounted. When you
adjust your brackets so they are in the same horizontal and vertical plane, the Shadow 8
transmitter and receiver should align.
If the Machine Run/Stop LED is not illuminated green after adjusting the mounting brackets,
your Shadow 8s probably have an internal problem. Call Wintriss Tech. Support for
assistance.
Power down the control before connecting or disconnecting the wires to the heads.
NOTICE
Содержание Shadow 8
Страница 95: ...1139300 Shadow 8 User Manual 3 10 Operation ...
Страница 107: ...1139300 Shadow 8 User Manual 4 12 Troubleshooting ...
Страница 111: ...1139300 Shadow 8 User Manual B 2 Checkout Procedure Log ...
Страница 113: ...1139300 Shadow 8 User Manual C 2 Test Procedure Log ...
Страница 135: ...1139300 Shadow 8 User Manual D 22 Extracts from OSHA and ANSI ...
Страница 136: ...Shadow 8 User Manual 1139300 Extracts from OSHA and ANSI D 23 ...
Страница 137: ...1139300 Shadow 8 User Manual D 24 Extracts from OSHA and ANSI ...
Страница 143: ...1139300 Shadow 8 User Manual I 4 Index ...
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......