Shadow 8 User Manual
1139300
Operation
3-7
c. Wait a few moments, then turn the Program/Run/Start key switch to PROG again, and
release the switch. The red and amber LEDs and blanked IBIs continue flashing; the
yellow Interlock/Alarm LED illuminates.
d. Release the Program Off/On key switch, allowing it to return to OFF. The red and
amber LEDs and blanked IBIs continue flashing, and the yellow LED remains lit.
3.
Turn the Program/Run/Start key switch to the START position to reset the unit. Shadow 8
enters the Curtains Unobstructed state (i.e., Machine Run/Stop LED indicator is lit green).
The amber Blanking Active LED becomes steadily illuminated, and the red IBIs in the
obstructed area are lit continuously.
To program a new fixed blanking window or no blanking window, perform steps 1 through 3
using a new object or no object.
Setting a Floating Blanking Window
Wait at least half a second but no more than 10 minutes before turning the Program/Run/
Start key switch to the PROG position a second time.
If you remove the object while fixed blanking is active, you can return it to the same position without
having to reprogram fixed blanking. Simply replace the object in the area defined by the illuminated
Individual Beam Indicator LEDs. If Shadow 8 is in Start/Restart Interlock mode, you must reset the
system after replacing the object by turning the Program/Run/Start key switch to START.
OBSERVE CORRECT SAFETY DISTANCE WHEN USING FLOATING WINDOW
• Ensure that the correct safety distance exists between the light curtain and the hazardous area.
See Calculating the Safety Distance, page 2-2 for detailed information on object sensitivity,
depth penetration factor, and OSHA and ANSI safety distance formulas.
• Add 2.69 in. (68.3 mm) to the calculated safety distance for the one-beam floating blanking
window (see Increasing Safety Distance To Compensate for Blanking Windows, page 2-10).
• Place ability to set floating blanking windows under supervisory control to avoid unauthorized usage.
Failure to comply with these instructions will result in death or serious injury.
MARK CORRECT MINIMUM OBJECT RESOLUTION ON SERIAL NUMBER LABELS
During installation strike out with a permanent marker the minimum object resolutions printed on
the serial number labels of receivers and transmitters that do not apply to your system. Make sure
to adjust the object resolution based on any blanking windows that have been set (see Increasing
Safety Distance To Compensate for Blanking Windows, page 2-10). Four object resolutions are
printed on each label.
NOTICE
NOTICE
DANGER
!
NOTICE
Содержание Shadow 8
Страница 95: ...1139300 Shadow 8 User Manual 3 10 Operation ...
Страница 107: ...1139300 Shadow 8 User Manual 4 12 Troubleshooting ...
Страница 111: ...1139300 Shadow 8 User Manual B 2 Checkout Procedure Log ...
Страница 113: ...1139300 Shadow 8 User Manual C 2 Test Procedure Log ...
Страница 135: ...1139300 Shadow 8 User Manual D 22 Extracts from OSHA and ANSI ...
Страница 136: ...Shadow 8 User Manual 1139300 Extracts from OSHA and ANSI D 23 ...
Страница 137: ...1139300 Shadow 8 User Manual D 24 Extracts from OSHA and ANSI ...
Страница 143: ...1139300 Shadow 8 User Manual I 4 Index ...
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......