AutoSet User Manual
1137200
Installation
2-27
8.
Run a communications cable between the AutoSet and SmartPAC and wire both ends to
the appropriate connector, repeating steps 1 through 4 of the
procedure, page 2-23. Refer to Table 2-11 for wiring connections.
* Shield should be connected to ground stud on enclosure
nearest entry of communications wiring (see Figure 2-12).
9.
If you have not installed a zero cam switch and wired a zero cam input to your AutoSet,
wire the SmartPAC zero cam output (pin #211 on TB101 on the SmartPAC processor
board) to the AutoSet input (pin #2 on TB101A or TB101B) on the AutoSet processor
board. You can run the zero cam wiring through the same conduit as the communications
wiring used in step 8.
10.
Power up SmartPAC.
11.
If you replaced the SmartPAC firmware, access the SmartPAC Main Initialization Menu
and enter the brake monitor settings (select SET BRAKE MONITOR) and cam channel
names (select SELECT CAM NAMES) you recorded in step 2, referring to your
SmartPAC user manual, if necessary.
12.
Select TONNAGE MONITOR on the Main Initialization Menu to display the Tonnage
Monitor Initialization Menu.
13.
Select INITIALIZE PARAMETERS on the Tonnage Monitor Initialization Menu. Press
ENTER when the warning message displays to confirm that you want to continue with
initialization.
14.
Set the capacity of your press on the Tonnage Monitor Initialization Menu, and enable or
disable the repeatability setpoint, the startup counter, and setup mode.
15.
Select SECURITY ACCESS on the Tonnage Monitor Initialization Menu, and configure
AutoSet security the way you want it.
16.
When you are ready to make parts, go to Program mode and enter setpoint percentages
and a sample period setting for each tool programmed in SmartPAC, referring to your
SmartPAC user manual for assistance.
17.
Return the obsolete SmartPAC firmware board and the old AutoSet firmware chip to
Wintriss.
Table 2-11. Communications Wiring Connections: AutoSet and SmartPAC
AutoSet
TB104
Pin # *
SmartPAC
TB102
Pin # *
1 (GND)
240 (GND)
2 (+TXD)
241 (+RXD2)
3 (-TXD)
242 (-RXD2)
4 (+RXD)
243 (+TXD2)
5 (-RXD)
244 (-TXD2)