To set the number of strokes in the sample period, follow these steps:
1.
Open the cover of the AutoSet enclosure and locate the Mode switch block (S101) just to
the right of the ribbon cable connector on the left side of the AutoSet processor board (see
Figure 4-2).
Mode switch #1 controls the length of the sample period and is set at the factory to the
OFF position (left side of S101), which specifies a sample period of 15 strokes, as shown
in Figure 4-2.
2.
To change the sample period setting to 1 stroke, move switch #1 to the right, or ON,
position, using a ballpoint pen or small screwdriver.
3.
To reset the sample period to 15 strokes, move switch #1 to the left, or OFF, position.
4.
On standard AutoSets, press the RESET button on the front panel and hold it for at least
two seconds until the Setpoints displays flash and the setpoint readings change to 120% of
full-scale tonnage
or
On AutoSet Plus units, turn the DISPLAY switch on the front panel to the “RESET”
position and hold it for at least two seconds until the Setpoints displays flash and the
setpoint readings change to 120% of full-scale tonnage.
A new sample period will be initiated the next time you run the press.
Figure 4-2. AutoSet 1504 Processor Board: Mode Switch #1 Set to OFF
(15-Stroke Sample Period)
F101
T101
HI NEU GND GND N/O C
TB103
TB101A
P102
TB104
10 9 8 7 6 5 4 3 2 1
5 4 3 2 1
5 4 3 2 1
RIGHT FRONT
5 4 3 2 1
LEFT FRONT
5 4 3 2 1
RIGHT (REAR)
5 4 3 2 1
LEFT (REAR)
1
2
3
4
5
6
7
8
S101
REM RST
Z CAM
SETUP
RESET
REP SEL
REV SEL
J115
R144
J116
R133
J117
R161
J118
R173
0
4
6
2
8
0
4
6
2
8
1 2
8
7 6
5
4
9
3
0
1 2
8
7 6
5
4
9
3
0
1 2
8
7 6
5
4
9
3
0
%TOL
%REP
S104
S107
S105
S106
S103
TONNAGE
100s
1s
10s
S102
ZERO SET
CALFACTOR
115V
K101
DS109
Rx
Tx
DS107
DS106
XU106
+5V
DS1
10
part no. 9644202
AUTOSET
4CH
Version 1.67
OPERATE
DS111
DS112
+12V
- 12V
F102
1/4 AMP
250VAC
4 AMP
250VAC
TB105
TB108
TB107
TB106
6 5 4 3 2 1
DS101
DS102
DS103
DS108
DS104
DS105
MODE
S110
1
2
3
4
5
6
7
8
S101
MODE
ON
15 strokes
1 stroke
Sample Period
Содержание autoset 1500
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 84: ...1137200 AutoSet User Manual 4 16 Operation ...
Страница 96: ...1137200 AutoSet User Manual A 4 Wiring and Settings Tables ...
Страница 102: ...1137200 AutoSet User Manual Wintriss Manuals ...