AutoSet User Manual
1-4
Introduction
•
DISPLAY Switch.
This switch is found only on AutoSet 1500 Plus and 1504 Plus models.
It has three settings: from left to right, REPEATABILITY, HIGH, and RESET.
When the switch is set to “HIGH,” the Setpoints LED displays show setpoints for high
tonnage.
When the switch is turned to the “REPEATABILITY” position, repeatability setpoints
appear in the Setpoints displays.
The “RESET” position has the same functionality as the RESET button on standard
AutoSet 1500 and 1504 units. Turning the switch briefly to “RESET” (i.e., for less than
two seconds) resets the load analyzer after a fault. Turning the switch to the “RESET”
position (and holding it there) for more than two seconds signals AutoSet to recalculate
setpoints.
•
Zero Cam LED
. Illuminates when the zero cam switch is on (i.e., between 240
o
and 30
o
).
The zero cam, which is standard on AutoSet 1500 Plus and 1504 Plus analyzers but
optional on standard 1500 and 1504 AutoSets, clears the tonnage reading for the previous
stroke so the tonnage reading for the current stroke can be displayed.
•
REVERSE Button.
This button appears only on AutoSet 1500 Plus and 1504 Plus units.
Pressing the REVERSE button causes reverse tonnage values to replace forward tonnage
readings in the Load LED displays. The abbreviation “rEV” appears in the Setpoints LED
displays to indicate that reverse tonnage is being shown. Pressing the REVERSE button
again returns the Load LED displays to forward tonnage values.
•
Keylock and Screws
(AutoSet 1500 and 1500 Plus). The keylock enables the AutoSet
enclosure to be locked and the key removed, preventing unauthorized changes to settings.
In addition, the cover can be secured to the enclosure with two Phillips screws. To make
settings inside the enclosure, simply loosen the screws, turn the keylock to its “open”
position, and swing the cover open.
•
Keylock and Cover Latches
(AutoSet 1504 and 1504 Plus). The keylock on AutoSet
1504 and 1504 Plus units is located on the right side of the enclosure rather than on the
cover but, otherwise, functions identically to the keylock on AutoSet 1500 and 1500 Plus
load analyzers. The cover can be secured to the enclosure with two latches, located on the
enclosure’s right side. To make settings inside the enclosure, simply release the latches,
turn the keylock to its “open” position, and swing the cover open.
Strain Links
AutoSet receives its tonnage information from strain links, which are mounted to the press
frame or other structural members and wired to the load analyzer. Strain links measure the
forces acting on the press frame, converting press frame deflection into an electrical signal.
This signal is proportional to the load being generated by the press.
Two strain links are used with AutoSet 1500 and 1500 Plus models, four strain links with
AutoSet 1504 and 1504 Plus units. Instructions on how mount and wire strain links are
provided starting on page 2-10. Zeroing strain links is covered starting on page 3-1.