Troubleshooting
Power Supply LEDs, +5V and ±12V
The three green LEDs labelled “+5V” (DS110), “+12V” (DS111), and “-12V” (DS112),
which are located in the upper left corner of the AutoSet processor board, indicate whether
+5V, +12V, and -12V circuits providing power to the board are energized. All three LEDs
should normally be on. If all three LEDs are off, check the input power connections at
TB103. If input power connections check out, and all three LEDs are still unlit, call Wintriss
Tech. Support. Also contact Wintriss Tech. Support when only one or two LEDs are unlit.
Relay Status LED
The LED labelled DS109, located just below the solid-state output relay K101 at the top right
of the AutoSet processor board, indicates the status of the K101 relay. When the relay is
energized, DS109, which is red, is illuminated. When the relay is de-energized, indicating
that a fault condition has occurred and a stop signal has been sent to the press, DS109 turns
off.