AutoSet User Manual
1137200
Installation
2-23
Refer to Figure 2-7, page 2-9 if you need help connecting the wires to the terminals.
Make sure not to wire the connector backwards.
4.
Plug the connector back into the TB101B or TB101A terminal block. The connector can
be plugged in only one way. Check the wiring connections to make sure they are correct.
5.
Make sure that switch 5 on Mode switch block S101 on the AutoSet Processor board is set
to the OFF position, its default setting. This position enables Setup Mode. (To disable
Setup Mode, move the switch to its ON position.)
Connecting an AutoSet to SmartPAC
The following sections show you how to connect an AutoSet to either SmartPAC 2 or the
original SmartPAC. Up to two AutoSets can be connected to a single SmartPAC.
Connecting an AutoSet to SmartPAC 2
To connect an AutoSet to a SmartPAC 2 control, perform the following steps, referring to
your SmartPAC 2 user manual for help:
1.
Locate terminal block TB103 on the SmartPAC 2 processor board and terminal block
TB104 on the AutoSet 1500 (see Figure 2-4) or 1504 (see Figure 2-5) processor board.
2.
Run the five-conductor shielded communications cable through flexible, liquid-tight, low-
voltage conduit from SmartPAC 2 to AutoSet. If you have SmartPAC 2 and AutoSet
enclosures, they are rated NEMA 12 (protected against dust and oil). You must use
Table 2-9. Setup Mode Circuit Wiring Connections, TB101B or TB101A
AutoSet Model
Terminal Block
Pin #
Label
1500 Plus
TB101B
8
Setup
10
Ground
1504 Plus
TB101A
5
Setup
10
Ground
Make sure that the Setup Mode circuit is connected so the Setup Mode input is pulled to
ground when the press control is set to “Inch” and is open when not in “Inch.” Refer to
your electrical prints or the manual for your press control to plan your wiring.
If your AutoSet firmware version is 2.27 or higher, you do NOT need to replace the firmware chip
when connecting the AutoSet to a SmartPAC control. You must, however, do the following on the
AutoSet board:
• Set all Tonnage indicator dials to zero
• Set the Zero Set/Operate/Calfactor toggle switch (S102) to “OPERATE”
NOTICE
NOTICE