FURNACE INSTALLATION – LOCATION
Continued:
When installing your WinterGreen Furnace it is important to adhere to the clearance dimensions
to combustible surfaces as shown below. Note that these are minimum clearances and your fur-
nace should never be located any closer than the dimensions stated.
IMPORTANT:
The installation of this furnace must comply with the latest edition of NFPA 211 for Reduced
Clearances and/or your local building codes, whichever minimum clearances are greater.
Installation should be made by a qualified heating equipment installer (one who is engaged and
is responsible for, or is thoroughly familiar with the installation and operation of gas, oil and
solid fuel burning appliances; who is experienced in this type of work and familiar with all the
building code requirements and/or fire codes of the authority having local jurisdiction.)
NOTE: Any connections to an existing ductwork system of a forced air heating system must
comply with NFPA 90B, 2-1.1 and have plenums constructed of metal in accordance with NFPA
90B, 2-1.3. Contact your local H.V.A.C. professional for determining compatibility of the
WinterGreen Furnace to your existing heating system prior to installation.
NOTE: The furnace should be placed on a non-combustible floor made of concrete or masonry.
Consideration should be made when deciding a location for the furnace; it should be close to a
chimney, a power source and have easy accessibility to your wood supply. If your WinterGreen
furnace is to be located in a garage, National Codes require that the lowest point of ignition be at
least 18” from the floor. If the furnace is to be installed in a separate enclosed space where com-
bustion air is taken from outside the garage, this rule does not apply.
Top View
Содержание IM-130
Страница 8: ...WARNINGS SAFETY SAFETY LABEL LOCATIONS...
Страница 16: ...FURNACE COMPONENT LIST...
Страница 35: ...WOOD SELECTION CHART The Weights and Measure Act states that a cord of wood is 4 ft x 8 ft x 4ft 128 cu ft...
Страница 54: ...PLUMBING INSTALLATION...
Страница 57: ...WIRING CONTROLS Control Panel Components Figure 2 Control Panel FUSE...
Страница 65: ...TROUBLESHOOTING GUIDE...