3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
5044745
65
Installation, Operating and
Maintenance Instructions
1
5
2
6
7
3
white + 24 V DC
brown 0 V
green
yellow
grey
battery pack
pink
(not assigned)
Figure 3.8.2-6: Wiring blueMotion with fingerprint
ekey Integra with control
unit and frame power supply
(sash side)
1
Description
1
Set of cable transition T-SET KÜ-T1 FT
INTEG-BM 3,5 + 1,5 M EST including
housing EV-G + cover plate (depends
on the faceplate / material type), plug-in
(Art.-No. 5040512)
2
Cable transition frame part
T-KÜ-T1 RT KABEL 0,6M RNT, for
frame power supply (Art.-No. 5040504)
3
T-BM ... including motor housing,
Art.-No. on request
4
Frame power supply T-NETZTEILRAHM.
24 V DC 1 A (2 A/2 S) (Art.-No. 5038589)
4
230 V AC
Description
5
-
7
ekey Article in PACKAGE:
for timber doors / radius 20 mm = 101941
for aluminum and PVC / square 24 mm
= 101942
5
Fingerprint ekey home FS IN 2.0 T BT
+ decor design element FS IN ED
6
Control unit ekey home SE integra 1
7
ekey KAB A 4 m / 4 x 0,14 RJ / CP,
Connection from ekey fingerprint to
control unit ekey home integra
}
external opening
signal
X3: Connection from
control unit ekey to
the fingerprint
JP1: Adjustment 2 / 3
JP2: for relay 2
X6: Screw-type
terminal, Connection
from wire yellow, green
(relay 1)
yellow = switching pulse
green = switching pulse
X1: Connection from
housing EV-G of the
control unit, wire red
for relay 2 at Integra 2
green / yellow
= input for external
potential-free contact
(e.g. unlocking via inter-
com / "open" button)
grey
= with battery pack - on terminal
PFS
= without battery pack - together
with white on + 24 V DC terminal
Notice!
max. 40 m extendable
(min. 5 x 0,8 mm
2
)