InfoWIN Touch display and operating unit
2.
InfoWIN Touch display and operating unit
The InfoWIN Touch display is a central display and operating unit with integrated web server for operating the boiler,
buffer load function module, heating circuit function module, etc.
The function modules are only shown on the display
when they are available
and in the server level set by a trained member of service personnel.
During operation, the homescreen (title screen) is displayed by default and the LED lights up green – Fig. 2. After
approx. 12 min., the screensaver turns on (screen is black) and only the LED is lit up green. Pressing the touchscreen
reactivates it.
The InfoWIN Touch is fitted with a LAN and LON connection, an LED, a micro SD card and a reset button.
1 ........... LED
2 ........... Reset button
3 ........... LON connection / 12 V DC
4 .......... LAN connection
5 ........... micro SD card slot and micro SD card
2
4
5
Fig. 2
Front side of the Info Touch
Fig. 3
Rear side of the Info Touch
1
3
LAN connection
There is an RJ45 socket on the InfoWIN Touch for the LAN connection. Use a standard LAN cable to connect the
InfoWIN Touch with your Internet router (Internet modem). Alternatively, the InfoWIN Touch is suited to all LAN con-
nection types, such as Powerline and PowerLAN, also known as dLAN.
LON connection
The InfoWIN Touch is operated at an operating voltage of 12 V DC. A 4-pole cable is used to connect the InfoWIN Touch
to the boiler control panel. This cable connects the supply voltage and the LON field bus (data bus for communicating
with control components).
micro SD card
The microSD card is required for software update.
Reset button
If the reset button is pressed for more than 10 sec., the user name and password for the integrated web server in the
InfoWIN Touch are reset to the factory settings.
Factory settings:
User name:
Service
User name:
USER
Password: 123
Password: 123
These passwords are automatically overwritten with a secure password the first time a connection is established to the
"WindhagerConnect" portal.
LogWIN
65
°C
Modulation mode
Information level