27
4.
Operating phases
4.
Operating phases
The relevant operating phase is displayed on the boiler homescreen – Fig. 60.
Stand-by
The boiler is ready for starting (see LogWIN operating manual).
After 12 min., the display goes dark; only the green LED is lit up.
Stand-by off period
The automatic boiler is locked out.
Pressing the
Cancel
button cancels the "Stand-by off period" operating phase and switches to the operating phase to
"Stand-by".
Cladding door open
If the cladding door is opened, "Cladding door open" is displayed for as long as it remains open.
Ignition ready
1
The boiler is prepared for automatic ignition mode.
Pressing the
Cancel
button cancels the "Ignition ready" operating phase and switches to the operating phase to "Stand-by".
Ignition phase
1
The boiler is in automatic ignition mode. Once the ignition phase is complete, the system switches to the "Start proce-
dure" operating phase.
Pressing the
Cancel
button cancels the "Ignition phase" operating phase; the blower runs for a further 2 minutes before
switching to the "Stand-by" operating phase.
Start procedure
The start procedure is started automatically once the ignition phase
1
is complete or the cladding door is closed. Once
the "Start procedure" operating phase is complete (at least 30 min.), the system switches into the "Modulation mode"
operating phase.
The start procedure is cancelled by pressing the
Cancel
button or automatically after around 15 min. if the combustion
chamber temperature is not increasing sufficiently. The system them switches into the stand-by operating phase.
Flame stabilisation
Once combustion has been interrupted, an attempt is made to build constant combustion back up and the system then
changes into the "Modulation mode" or "Stand-by" operating mode.
Fig. 60 Homescreen
Operating phase display
1
Only for LogWIN with automatic ignition (accessories).
LogWIN
75
°C
Modulation mode
Information level