35
3.
Care, Cleaning, and Maintenance
3.5 Exhaust pipe to flue
Clean/vacuum out the exhaust pipe (pipe connecting the boiler and flue) around the cleaning aperture.
Information!
Be careful of the sensors in the flue outlet when cleaning the exhaust pipe - do not bend or damage
them. No warranty claims will be accepted for damage resulting from incorrect cleaning!
3.6 Pellet storage room or storage container
Attention!
Please also note the hazard information in section 1.3.3. ”Entering the pellet storage room/storage
container.” Do not attempt to enter an unventilated storage room (particularly buried tanks).
Information!
When entering the pellet storage room or storage container, do not stand on the pellets surroun-
ding the suction probe.
Before filling the pellet storage room or storage container, check the following:
– whether the storage room is free of foreign bodies.
– whether a lot of dust has settled on the floor over time.
Please note: A layer of dust on top of the pellets is normal because dust present migrates to the surface when
the pellets gush out during removal.
– whether pellets have swelled up against the wall if the storage room is not fully dry.
Tip!
Leading pellet suppliers recommend fully emptying the storage room every 2–3 yearsto ensure
that there is sufficient turnover of pellets (so old pellets do not remain in the hopper). Automatic
changeover between the three suction probes can be deactivated using the InfoWIN
PLUS
(see Ma-
nual operation InfoWINPLUS). This allows you to fully empty the storage room for one probe. You
can then continue heating with the other suction probes. If you perform this task every year with a
different probe, you will “replace” your entire supply of pellets regularly.