44
2.
Operation
2.10 Heating system operation
The BioWIN 2 should not be switched off with the On/Off switch
on the InfoWINplus or disconnected from the
power supply via the power plug. The heating system should be shut down by switching it off at the control system
(see section 2.10.1 and 2.10.2).
Attention!
The anti-freeze function is not active when the boiler is shut off (ON/OFF button
) .
Information!
The block protection for cleaning the heating surfaces and for the ash conveyor (is switched on
briefly every day at 12.00) is not active when the boiler is switched off (ON/OFF button
).
2.10.1 BioWIN 2 with MESplus system control
Information!
For operation of the MESplus and related user modules, please see their respective Operating
instructions.
Boiler switching on, MESplus system control to automatic operation:
1. Press the ON/OFF button
on the InfoWINplus panel, the lighting and display are switched on, the signal
lamp lights green and a self-test is performed (see also section 2.6.2). After a successful self-test and if a
setpoint is transferred by the system control, the BioWIN 2 automatically starts operation.
2. Set the
operating mode switch
(es) on the MESplus control module(s) to “
Automatic operation
”
. The sy-
stem operation (setting temperatures and operating times) is performed using the user module (installed in
the living area) – for more details, please refer to the instructions.
Fig. 118 BioWIN 2 with MESplus system control
ON/OFF button
InfoWINplus operating unit
Operating mode switch
Switching off heating system:
Set the operating mode to “Standby”
using the user module (installed in the living area).