2.
Operation
Confirm the selected sub-menu “Feed operating mode”
by pressing the
Choose
button – Fig. 77.
The
factory setting
for the “Feed operating modem”
menu item is
“switched off”
.
with enable time:
Select this if the feed noise (suction
turbine) can be heard or is disruptive in the living
area.
Functional description: The pellet feed is enabled
during a time period that can be set (see page 34)
and is automatically started at this time if required.
The reserve supply container is refilled full at the
end of the enable time, if required.
Tip!
A complete fill sucks in about 50 kg of pel-
lets. The pellets required during the blo-
cked time must not exceed this value!
Burning duration with 50 kg pellets
BioWIN
Burning duration at nominal output
BW 102
19 h
BW 152
14 h
BW 212
10 h
BW 262
8 h
Feed operating mode
With enable time
With start time
Without time control
Switched off
Choose
Back
Fig. 77
Confirm stage 1 cleaning
Confirm stage 2 cleaning
Pellet consumption
Time
Feed operating mode
Time profile feed
Choose
Back
Fig. 78
The
arrow
buttons select the required sub-menu –
Fig. 78.
Pressing the
Save
button saves the changed “Feed
operating mode” – Fig. 79. The display shows “Parameter
is saved” for a few seconds (Fig. 80) and then changes
back to the previous level – Fig. 81.
with start time:
Select this if you want the feed to start
at the same time every day.
Functional description: The reserve supply contai-
ner is filled every day if required at the set time (see
page 36). Interim fills are also performed if the filling
amount is not sufficient for 24 hours.
without time control:
Select this if the feed noise (suc-
tion turbine) cannot be heard or is not disruptive in the
living area.
Functional description: The pellet feed is automati-
cally switched on if required at any time.
Fig. 79
Feed operating mode
With enable time
With start time
Without time control
Switched off
Save
Back
Confirm stage 1 cleaning
Confirm stage 2 cleaning
Pellet consumption
Time
Feed operating mode
Time profile feed
Choose
Back
Fig. 80
Parameter is saved
(Animated symbol)
The menu item or sub-menu item is exited by pressing
the
Back
button (Fig. 81) or after a delay of 10 minutes.