Winco PSS12H2E Скачать руководство пользователя страница 4

4

REV F

60706-209

SAFETY INFORMATION

This engine generator set has been designed and manufactured to 

allow safe, reliable performance. Poor maintenance, improper or 

careless use can result in potentially deadly hazards; from electrical 

shock, exhaust gas asphyxiation, or fire. Please read all safety 

instructions carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all warnings on 

the unit labels and in the manuals.

CALIFORNIA PROPOSITION 65

WARNING: 

This product contains crude oil, gasoline, 

diesel fuel and other petroleum products, Antifreeze to 

which can expose you to chemicals including toluene 

and benzene, Ethylene glycol (ingested) which are 

known to the State of California to cause cancer, birth defects or other 

reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

ANSI SAFETY DEFINITIONS

DANGER:

DANGER indicates an imminently hazardous situation which, if not 

avoided, will result in death or serious injury. This signal word is to be 

limited to the most extreme situations.

WARNING:

WARNING indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury.

CAUTION:

CAUTION indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury. It may also be used to 

alert against unsafe practices.

1. ELECTRICAL SHOCK -

The output voltage present in this equipment can cause fatal electric 

shock. This equipment must be operated by a responsible person.

 

A. Do not allow anyone to operate the generator without proper 

   instruction.

 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or snow.

 

E. Use only three-pronged grounded receptacles and extension 

   cords.

 

F. Be sure the unit is properly grounded to an external ground rod 

 

  driven into the earth.

2. FIRE HAZARD - 

Gasoline and other fuels present a hazard of possible explosion and/

or fire.

 

 

A. Do not refuel when the engine is running or hot.

 

B. Keep fuel containers out of reach of children.

 

C. Do not smoke or use open flame near the generator set or fuel 

   tank.

 

D. Keep a fire extinguisher nearby and know its proper use.  

 

  Fire extinguishers rated ABC by NFPA are appropriate.

 

E. Store fuel only in an approved container, and only in a well 

 

  ventilated area.

 

F. Follow local codes for closeness to combustible material.

3. DEADLY EXHAUST GAS - 

Exhaust fumes from any gasoline engine contain carbon monoxide, an 

invisible, odorless and deadly gas that must be mixed with fresh air.

 

A. Operate only in well ventilated areas.

 

B. Never operate indoors including attached garages

 

C. Never operate the unit in such a way as to allow exhaust gases  

 

  to seep back into closed rooms (i.e. through windows, walls, 

 

  floors).

4. NOISE HAZARD - 

Excessive noise is not only tiring, but continual exposure can lead to 

loss of hearing.

 

A. Use hearing protection when working around this equipment for 

 

  long periods of time.

 

B. Keep your neighbors in mind when using this equipment.

5. CLEANLINESS - 

Keep the generator and surrounding area clean.

 

A. Remove all grease, ice, snow or materials that create 

 

  slippery conditions around the unit.

 

B. Remove any rags or other materials that could create a  

 

  potential fire hazard.

 

C. Carefully clean up any gas or oil spills before starting the unit.

6. SERVICING EQUIPMENT -

All service, including the installation or replacement of service parts, 

should be performed only by a qualified technician.

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or receptacle 

 

  panels while the engine is running.

 

D. Use extreme caution when working on electrical components. 

 

  High output voltage from this equipment can cause serious 

 

  injury or death.

 

E. Always avoid hot mufflers, exhaust manifolds, and engine parts. 

 

  They can cause severe burns instantly.

 

F. The use of the engine-generator set must comply with all  

 

  national, state, and local codes.

Содержание PSS12H2E

Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS PSS12H2W E F GENERATOR MANUAL...

Страница 2: ...GER SOLAR CHARGER OPTION 10 AC ELECTRICAL CONNECTIONS 11 GENERATOR CONNECTIONS WINCO UL ATS ASCO 185 DC ELECTRICAL INTERCONNECTION 12 ASCO 185 UL SWITCH INITIAL START UP 12 START UP PROCEDURE CUSTOMER...

Страница 3: ...xpect from WINCO should you need service assistance in the future COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours If you should ever need to contact...

Страница 4: ...the earth 2 FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C...

Страница 5: ...recommended The transfer switch is UL1008 approved A fourteen day electronic exerciser circuit is installed in the ATS as standard equipment The ATS also contains the power failure sensing circuitry...

Страница 6: ...isfactory system installation The information in this manual is offered only as a guide to finalizing your installation plans ENGINE GENERATOR SET MOUNTING WARNING PERSONAL INJURY The enclosures on th...

Страница 7: ...ng located on the left side of the engine generator set This fitting is shipped with a plastic plug installed to insure the fuel system stays clean For all vapor fuel systems the delivery pressure of...

Страница 8: ...load Line PSI 10 15 lbs 7 11 in 4 6 oz 7 11 in 4 6 oz Full load Line PSI 10 15 lbs 7 11 in 4 6 oz 7 11 in 4 6 oz Natural gas Ref 2 3 4 Unit off 2 PSI 7 11 in 4 6 oz 7 11 in 4 6 oz Starting 2 PSI 7 11...

Страница 9: ...charger has an indicator light on it Red indicates it is charging and green indicates it is in storage mode float charge This charger is INSTALLING THE BATTERY CAUTION In the following battery install...

Страница 10: ...not intended to recharge a battery which has become completely discharged It is designed to produce enough current to recharge a slightly low battery and maintain a fully charged battery SOLAR CHARGER...

Страница 11: ...ed emergency distribution panel must be installed All selected emergency circuits are removed from main distribution panels and reinstalled in the emergency distribution panel Suggested circuits freez...

Страница 12: ...GRZQ OHDUDQFH IRU VHUYLFH DQG PDLQWHQDQFH RQ DOO VLGHV 3URSHU IXHO OLQH PDWHULDO DQG VL H OO IXHO OLQH FRQQHFWLRQV WLJKW XHO OLQH SURWHFWHG DQG D PRLVWXUH WUDS LQVWDOOHG PD EH required for NG 3 1 SUH...

Страница 13: ...DAMAGE SPEED ADJUSTMENTS SHOULD ONLY BE MADE BY A QUALIFIED SERVICE TECH NOTICE If for any reason during the check out procedures the Voltage and frequency are not correct press the red Stop Reset but...

Страница 14: ...utton to cancel the active time delay or exercise period stops the generator after cool down SET ENGINE EXERCISER Use this button to set the automatic exerciser INDICATOR LIGHTS On the front control d...

Страница 15: ...ITY LINE TO POWER BATTERY TENDER AND OPTIONAL ENGINE HEATER CUSTOMER GENERATOR OUTPUT CONNECTIONS TO EMERGENCY TRANSFER SWITCH EMERGENCY STOP CONTACTS PROVIDED FOR REMOTE EMERGENCY STOP SWITCH UNIT WI...

Страница 16: ...16 REV F 60706 209 SEQUENCE OF OPERATION UTILITY FAILURE...

Страница 17: ...CODES Auxiliary inputs can be user configured and will display he message as written by the user Fail to Start The engine has not fired after the preset number of start attempts Fail to Stop The modu...

Страница 18: ...ENTATIVE MAINTENANCE Reasonable care in preventative maintenance will ensure high reliability and a long life for the engine generator set and Automatic Transfer Switch WARNING When performing any typ...

Страница 19: ...8 Locked up engine generator set 9 Defective starter fuel solenoid relays ENGINE CRANKS BUT WILL NOT START 1 Improper fuel pressure being delivered to unit 2 Fuel supply shut off 3 Fuel supply empty...

Страница 20: ...20 REV F 60706 209 PAD LAYOUT DRAWING 21 11075 01 60706 209 ENGINE GENERATOR SET PAD LAYOUT...

Страница 21: ...TIONS ASCO 165 SERIES TRANSFER SWITCH 9 8 7 6 5 4 3 2 1 TB7 L6 NEUTRAL T B 4 3 2 1 L2 GROUND T B 9 POSITION CONNECTOR G1 N G3 GND N L1 GND 1 5 24 23 ES ES 2 4 1 24 22 1 23 CONTROL TOWER ENGINE CONTROL...

Страница 22: ...22 REV F 60706 209 SOLAR CONTROL PANEL IF EQUIPPED EXTERNAL RECEPTACLE ASSEMBLY IF EQUIPPED N N GND GND G1 G1 G3 G3 G3 G3...

Страница 23: ...23 REV F 60706 209 SOLAR PANEL ASSEMBLY IF EQUIPPED...

Страница 24: ...nd fitness for a particular purpose are limited to 12 months or 1000 hours which ever occurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some s...