Winco DR20I4-/1 Series Скачать руководство пользователя страница 11

11

OPM-135/C

STARTING PROCEDURE

CAUTION:

For the first 10 seconds of operation all of the oil, coolant, 

and electrical shutdowns are disabled. This is enough time 

to cause catastrophic damage to the equipment if the 

pre-start checklist is not properly completed and proper 

maintenance isn’t consistently followed.

NOTE: Cold start capabilities are strongly correlated with 

the quality of the diesel.

LUBRICATION

Before starting the engine, check the oil level in the 

crankcase. If it is low, refill to the full mark with the proper 

weight/grade of oil as recommended by the engine 

manufacturer’s maintenance instructions. The necessity of 

using the correct oil, and keeping the crankcase full, cannot 

be over emphasized. Failure to use the proper oil and keep 

the crankcase properly filled will cause excessive engine 

wear and shorten its useful life.

WINCO recommends our 5W-30 fully synthetic heavy duty 

engine oil to give you maximum cold weather protection 

while maintaining excellent performance in warmer 

weather. We have partnered with a national lubrication oil 

manufacturer to give you access to Winco private branded 

premium oil available at comparable prices to conventional 

oils. See your dealer for additional information.

Qty of oil

SAE 

Grade

Base Stock

International 

specifications

Sulfur 

Content In 

The Fuel

WINCO 
Broad Range

5W-30

Synthetic

API CJ-4

ACEA E6/E9

< 15 ppm

Premium

10W-40

Semi-

Synthetic

API CJ-4

ACEA E6/E9

< 15 ppm

Not 
Authorized

Monograde

CAUTION: PERSONAL INJURY

Only check oil when the engine is not running and is at a 

low temperature in order to avoid the risk of burns.

  1. Remove the dipstick and ensure the oil level is between 

    the Min and Max limits.

  2. If it is difficult to read the level of the oil, clean the 

    dipstick using a clean cloth and then put it back into 

    its seat. Remove the dipstick again and check the level.

  3. If level is low, unscrew the cap and refill with 

    suitable oil using the previous table. 

COOLANT

Before starting the engine, check the coolant level in 

the radiator. If it is low, refer to Refilling Coolant in the 

Maintenance section of this manual. The radiator should be 

filled to about 1 inch below the filler neck. For additional 

information on engine coolant requirements, see engine 

manufacturer’s maintenance instructions.

CAUTION:

Both too high and too low of coolant temperature can 

cause an engine malfunction. While the engine is running, 

ensure the coolant temperature is within appropriate 

temperature (167 - 194

°

F).

PRE-START CHECK LIST

There is a Pre-Start & Warranty Form that must be filled out 

by an Authorized WINCO Service Center. After completing 

the checklist, the engine-generator set is ready for initial 

start-up. 

WARNING: EQUIPMENT DAMAGE:

Before attempting to start this unit, complete your pre-start 

checklist and ensure the generator mainline circuit breaker 

(if installed) is in the proper position prior to starting. 

Starting this unit without it properly connected can cause 

serious personal injury or equipment damage.

DO NOT jump start these engine-generator sets. Starting 

these units on a low battery or jump starting them will 

cause damage to the engine control module. 

Содержание DR20I4-/1 Series

Страница 1: ...AL 1 DEG ANGULAR 9 15 2016 ZJF COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours If you should ever need to contact us on this unit it will help us to...

Страница 2: ...FILTER CLEANING RADIATOR CHANGING THE FUEL FILTER STORAGE MAINTENANCE SCHEDULE TROUBLESHOOTING TABLE 16 ENGINE HARNESS SCHEMATIC 17 WIRING SIZE TABLE 17 DSE7310 WIRING DIAGRAM 18 WIRING DIAGRAMS 19 LI...

Страница 3: ...k exhaust gas asphyxiation or fire Please read all safety instructions carefully before installation or use Keep these instructions handy for future reference Take special note and follow all warnings...

Страница 4: ...everal of the major components also have their own individual data plates providing additional information to document build data for warranty and replacements parts Be sure to have the main WINCO uni...

Страница 5: ...enerator for operation take a couple of minutes to ensure the unit you have received is the correct model and review the specification pages in this manual to ensure that this unit meets your job requ...

Страница 6: ...aller The factory weather enclosures are acoustical housing intended for outdoor installation only Factory weather enclosed units are not intended to be used indoors and no support is available to ass...

Страница 7: ...pipe to aid your installation Ensure proper alignment with the generator The flex can be eliminated if it is pushed to one side to make a connection The most direct path possible should be used to ge...

Страница 8: ...ert the wire into the larger circular hole B Remove the screwdriver to secure the wire into place A B A C ELECTRICAL CONNECTIONS NOTICE CLASS 1 WIRING METHODS ARE TO BE USED FOR ALL FIELD WIRING CONNE...

Страница 9: ...ries of remote accessories that can help provide useful information to operators These accessories communicate over the DSE Net Terminal blocks are wired to the distribution panel to aid in installati...

Страница 10: ...must be clean and tight Depending on your battery type check the electrolyte in the battery periodically to be sure it is above the plates Never allow the battery to remain in a discharged condition...

Страница 11: ...N PERSONAL INJURY Only check oil when the engine is not running and is at a low temperature in order to avoid the risk of burns 1 Remove the dipstick and ensure the oil level is between the Min and Ma...

Страница 12: ...AC On three phase panels the G2 voltage level should also be checked ON 240 VOLT DELTA SYSTEMS BE SURE YOU KNOW WHERE THE HIGH VOLTAGE WILD LEG IS IT MUST BE IN THE SAME LOCATION ON THE LINE SIDE AS I...

Страница 13: ...not connected to a battery charger A solar charger kit is the easiest way to always maintain the battery during storage in mobile applications The supplied battery charger can be plugged in to an exte...

Страница 14: ...O NOT dispose or allow oil to seep into the ground or sewer systems doing so will cause environmental damage CHANGING OIL FILTER The filter must be replaced when the lubricant oil is changed Only use...

Страница 15: ...iquid in accordance to local codes DO NOT dispose or allow liquid to seep into the ground or sewer systems doing so will cause environmental damage CLEANING RADIATOR The surfaces of the radiator come...

Страница 16: ...citer stator AC short in the output leads Defective open generator output breaker Wiring error protective liquid ISO 4113 and introduce the liquid by pressurizing the circuit and driving the engine fo...

Страница 17: ...418 431 458 480 519 550 572 585 50 68 86 100 118 137 155 177 205 237 264 291 319 346 391 432 473 487 505 532 560 605 642 669 683 8 6 4 3 2 1 1 0 2 0 3 0 4 0 250 300 350 400 500 600 700 750 800 900 100...

Страница 18: ...18 OPM 135 C DSE7310 WIRING DIAGRAM...

Страница 19: ...WIRING DELTA SINGLE PHASE 120 240 VOLTS SINGLE PHASE AC WIRING 4 LEAD WIRING DIAGRAMS 24 60708 165 THREE PHASE AC WIRING HIGH AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS THREE PHASE HIGH WYE 277 480...

Страница 20: ...omponent of the product that is no longer manufactured or available Additionally WINCO Inc will not be liable for any engine replacement that may require an emissions tier level change THERE ARE NO EX...

Отзывы: