Shower control
SanTec PROOF S6
23
EN
PROOF S6
Assembly
7
7.
Feed the 2 x 0.5 mm
2
power connection cable and into the flush-mount
set and connect it to the power supply (art. no. 117 899 and art. no.
113 792).
Attention: The power supply must not be installed in the
flush-mount set!
8.
Connect the magnetic valves to the electronics module.
(red = therm. disinfection)
9.
Connect the power cables to the electronics module.
A
Thermal disinfection:
feed the control line
B
ON/OFF button:
see step 16
C
Infrared sensor: connection
with of the mounting frame
10.
Configure the desired functions at the electronics module
and insert the electronics module into the flush-mounted set.
11.
connect the power cables to the electronics module. Switch on the pow-
er supply (causing the safety locking mechanism of the magnetic valve
to activate).
11
9
8
A
B
C
10