Shower control
SanTec PROOF S6
19
EN
PROOF S6
Specifications
185
213
Operating voltage:
via power supply 230 V 50 Hz / 12 V=
Art.No. 117 899 - power supply for one control unit
Art.No. 113 792 - power supply for up to 5 control units
Power consumption:
max. 3.5 W
Magnetic valve:
cartridge 6 V
Active range:
Set to 70 cm by default (configurable from 30 - 70 cm)
Close-Active range:
4 - 5 cm
Flushing stop:
set to 10 min by default (configurable from 10 s - 10 min,
self-closing function: 10 s - 60 s)
Stagnation rinse:
for 10 s when not in use for 3–48 h (configurable, set to 48 h by default)
Cleaning stopp:
10 min (switchable)
Flow rate:
0,05 - 0,6 MPa (0,5 - 6 bar)
Static pressure:
max. 0,8 MPa (8 bar)
Water temperature:
max. 70 °C (max. 80 °C for max. 10 min)
Flow rate:
max. 22 l/min at 0,3 MPa (3 bar)
Water inlet:
R 1/2“ IG
Water outlet shower:
R 1/2“ IT
Noise class:
I
All dimensions in mm
:
tile
plaster
masonry
min 95
max 120
23
26
WW
R 1/2“ IG
122
45
CW
R 1/2“ IG
R 1/2” IG outlet to
showerhead
169
140
152
WW
R 1/2“ IG
CW
R 1/2“ IG
122
45
R 1/2” IG outlet to
showerhead
169
140
152
Models with thermal disinfection:
11
Electr. install-
ation pipe
for 12 V=
Electr. install-
ation pipe
for 12 V=