Maintenance
Maintenance Requirements
All maintenance must be
carried out with the
power switched off
.
Failure to comply may result in serious
injury!
On completion of maintenance, ensure that
replaced parts and/or any tools used have been
removed from the machine before starting it up.
Periodic Maintenance
Remove chips from the machine, preferably
with cloth)
Remove chips from the coolant tank and
change coolant regularly (see
Coolant
section)
Top up the coolant level (see
Coolant
)
Check the wear of the blade and change if
necessary (see
Changing the Saw Blade
)
Empty the chips out of the base.
Clean the vise and lubricate all the joints
and sliding surfaces, using good quality oil.
Attend to daily, weekly and annual
lubrication recommendations (see the
Lubrication
section)
Coolant
The
coolant tank access door
is located on the
back of the cabinet stand. Remove four hex cap
screws with a 5mm hex wrench. Check coolant
level in the coolant tank periodically and top off if
necessary. Coolant can also be added by
pouring directly on the table, which will drain into
the tank through the
chip strainer
.
Remove excess chips periodically from the tank.
Use the coolant level gauge to check the coolant
level.
Changing the Saw Blade
The cold saw must not be
connected to the power source when
changing saw blades. Failure to comply may
result in serious injury!
To change the saw blade:
1. Switch off the machine.
2. Release the lower disc guard.
3. Move the lower guard upwards.
4. Remove the blade and replace it with a new
one.
5. To secure the saw blade, reverse the
preceding steps.
Air Prep Unit – FK350-SX only
The
Air Prep Unit
regulates the air pressure
supplied to the saw. It is located in the cabinet
stand and is accessible through the access door
located below and to the left of the
control panel
.
Referring to Figure 13, it consists of a
pressure
regulator
,
pressure gauge
,
water trap
and
lubricator
. Air pressure (90lbs. minimum) is
supplied to the
air intake valve
located near the
bottom of the cabinet on the left side. The
pressure regulator
should be adjusted to 90–
120lbs.
Required Maintenance:
Check weekly.
Drain water from the trap when the level
exceeds the redline.
Adjust to 2 –3 drops/minute. Refill oil when
the level drops below the lower redline. Do
not exceed past the upper redline.
Figure 13
Содержание -SX
Страница 7: ...7 FK350 Features FK350 Cold Saw FK350 SX Cold Saw ...
Страница 21: ...21 Head Assembly FK350 FK350 SX ...
Страница 23: ...23 Power Feed Assembly FK350 SX ...
Страница 27: ...27 Stand Assembly FK350 SX ...
Страница 29: ...29 Base Assembly FK350 ...
Страница 31: ...31 Base Assembly FK350 SX ...
Страница 33: ...33 Manual Vise Assembly FK350 ...
Страница 35: ...35 Power Vise Assembly FK350 SX File 27 ...
Страница 37: ...37 Guard Assembly FK350 FK350 2SX ...
Страница 40: ...40 Pneumatic Drawing FK350 SX Wiring Diagram FK350 ...
Страница 41: ...41 Wiring Diagram FK350 SX ...
Страница 42: ...42 NOTES ...
Страница 43: ...43 NOTES ...
Страница 44: ...44 WMH Tool Group 2420 Vantage Drive Elgin Illinois 60124 Phone 800 274 6848 www wmhtoolgroup com ...