English INSTALLATION

5.3.6. 

Stationary dry well installation (version as unit)

In this installation type, the operating space 

is divided: collector tank and machine room. 

The fluid is collected in the collector tank, and 

the pump is installed in the machine room. The 

operating space must be blocked out as per 

the manufacturer’s configuration or consulting 

aid. The pump is connected to the suction- and 

pressure-side pipeline system at the specified 

point in the machine room. The pump itself is not 

immersed in the fluid.

The suction- and pressure-side pipeline sys-

tem must be self-supporting, i.e. it may not be 

supported by the pump. In addition, the pump 

connection to the pipeline system must be free 

of stress and vibrations. We therefore recommend 

using elastic connection pieces (compensators).

The following operating parameters must be 

complied with:

• 

The 

max. fluid temperature

 is 

70 °C 

(158 °F).

• 

Motor cooling

 - To ensure sufficient motor 

cooling by the motor fan, the minimum distance 

to the rear wall must be complied with. See the 

operating and maintenance manual for the motor!

• 

M

ax. ambient temperature

 - see the operating 

and maintenance manual for the motor.

The pump is not self-priming; therefore, the 

hydraulics housing must be completely filled 

with the fluid. Ensure that there is an appropri

-

ate inlet pressure. Air pockets are to be avoided 

at all costs. Appropriate ventilation systems 

must be provided!

Fig. 4.: Stationary dry well installation 

1 Gate valve inlet

5 Pump

2 Gate valve pressure 

pipeline

6 Attachment points for 

floor fixation

3 Non-return valve

7 Standard motor

4 Compensator

8 Coupling guard +  

coupling

Preparing the foundation

Fig. 5.: Drilling templates of the different baseplates

1.  Check foundation for correct version and sweep 

the surface clean.

2.  Use the drilling template to set the anchor bolts.

Please refer to the manufacturer’s instructions 

for information on concrete quality, edge dis-

tances and curing times!

Install the pump

1.  Check suction- and pressure-side pipeline system 

for tight fit.

The pipeline system must be self-supporting, 

i.e. it may not be supported by the pump!

2.  Fasten lifting equipment to the attachment 

points on the baseplate and position the pump in 

the planned location.

Caution! When draining the pump, make sure 

that the anchor rods enter exactly into the 

boreholes of the baseplate.

Caution! The baseplate must lie horizontally 

and completely on the foundation so that a 

torsion-free connection of the pipeline system 

is possible!

3.  Check the alignment and distances of the 

connection ports to the pipeline system. If the 

connection ports are not exactly level or plumb, 

or if the distances are not correct, the pump must 

be aligned accordingly via the baseplate, e.g. with 

compensating plates or levelling screws.

The deviation must not exceed ±0.5 mm 

(0.02 in) on 1 m (40 in)!

4.  Attach the pump to the foundation.

Refer to the manufacturer’s instructions for the 

tightening torques of the anchor bolts!

5.  Loosen the lifting gear.

Connect the pipeline system

Connect the suction- and pressure-side pipeline 

system.

To ensure that the pipeline system is connected 

free of stress and vibrations, we recommend 

using elastic connection pieces (compensators).

The forces and torques acting on the flanges 

must not exceed the following values!

Fig. 6.: Permissible forces on the suction and discharge ports 

Suction port

Type

Forces (daN)

Torques (daNm)

Fy

Fz

Fx

My

Mz

Mx

NORM-M15.77

240 216

268

92

106

130

NORM-M15.84

180 162

200

70

82

100

NORM-M25.61

298 270

334

126

146

178

RE 25.74E

322 400

358

172

198

242

RE 25.93D

322 400

358

172

198

242

NORM-M30.41

418 376

466

220

254

310

NORM-M50.21

718 646

796

576

664

808

Discharge port

Type

Forces (daN)

Torques (daNm)

Fy

Fz

Fx

My

Mz

Mx

NORM-M15.77

162

200

180

70

82

100

NORM-M15.84

162

200

180

70

82

100

NORM-M25.61

270

334

298

126

146

178

RE 25.74E

270

334

298

126

146

178

RE 25.93D

270

334

298

126

146

178

NORM-M30.41

322

400

418

172

198

242

NORM-M50.21

538

664

598

410

472

578

Содержание Wilo-Rexa NORM

Страница 1: ...6081510 02 04 2021 WH Pioneering for You Wilo Rexa NORM RexaNorm RE en Installation and operating instructions...

Страница 2: ...Fig 2 Fig 1 A B 8 9 10 2 4 4 7 5 5 3 1 2 7 1 6 3 6...

Страница 3: ...Fig 3B Fig 3A 1...

Страница 4: ...Fig 4 8 2 4 7 5 3 1 6 Fig 5 1 Rexa NORM M15 77 2140 1400 370 790 860 370 36 29...

Страница 5: ...Fig 1 150 0 3 1060 2100 2 6 900 0 3 900 0 3 1010 0 3 Fig 5 2 Rexa NORM M15 84 Fig 5 3 RexaNorm RE 25 74E RE 25 93D 1640 1060 290 600 660 36 29 290...

Страница 6: ...Fig 5 4 Rexa NORM M25 61 M30 41 Fig 5 5 Rexa NORM M50 21 26 665 665 665 26 150 26 26 2300 1010 1060 765 765 765 26 198 26 26 26 1450 1500 2691...

Страница 7: ...Fig 7 Fig 6 A A A A 2 4 4 5 5 5 5 5 5 3 1 S1 S1 X X Y Y Z Z Fz Mz My Mx Fy Fx...

Страница 8: ...Fig 9 Fig 8 2 3 1 2 4 5 3 1...

Страница 9: ...Fig 11 Fig 10 F2 F1 M1 M2...

Страница 10: ...Fig 13 Fig 12 D D L...

Страница 11: ...delivery 17 3 9 Accessories 17 4 Transportation and storage 17 4 1 Delivery 17 4 2 Transportation 17 4 3 Storage 17 4 4 Return delivery 18 5 Installation 18 5 1 General 18 5 2 Installation types 18 5...

Страница 12: ...iod is stipulated in the General Terms and Conditions Any deviations must be contractually agreed 1 4 3 Spare parts add ons and modifications Only genuine spare parts from the manufacturer may be used...

Страница 13: ...ng instructions in a language which the personnel can under stand Make sure that personnel are suitably trained for the specified work Ensure that safety and information signs mounted on the device ar...

Страница 14: ...ibility that people can come into contact with the motor and the fluid the connection must be equipped with an additional residual current device RCD The hydraulics must always be earthed In a standar...

Страница 15: ...n various standards are used as a basis for operating assembling and dismantling the pump 2 12 CE marking The CE marking is attached to the rating plate for the pump 3 Product description The pump is...

Страница 16: ...ulics must not be operated in an explo sive atmosphere 3 4 Operation with frequency converters Operation on a frequency converter is possible NOTICE Also note all the information in the operating and...

Страница 17: ...oted on the freight documentation 4 2 Transportation Only use lifting gear which is legally designated as such and officially approved The lifting gear must have sufficient bearing capacity so that th...

Страница 18: ...In order to prevent damage to the device or seri ous injury during installation the following points must be observed Installation work assembly and installation of the pump may only be carried out by...

Страница 19: ...to the baseplate using shackles Carrying straps wire ropes and plastic ropes or chains may be used as lifting equipment Bare shaft version The lifting equipment must be attached using a loop Chains m...

Страница 20: ...ons for information on concrete quality edge dis tances and curing times Install the pump 1 Check suction and pressure side pipeline system for tight fit The pipeline system must be self supporting i...

Страница 21: ...structions from manufacturer 4 Fasten the lifting equipment to the attachment points 5 Loosen the motor fixation on the baseplate 6 Slowly raise the motor by 1 2 mm 0 04 0 08 in 7 Place alignment plat...

Страница 22: ...aling chamber monitoring Before the pencil electrode is connected it must be checked with an ohmmeter The following values must be complied with This value must approach infinity If the values are low...

Страница 23: ...E Also note all the information in the operating and maintenance manual for the motor Operation on a frequency converter is possible The following parameters must be observed The standard speed of the...

Страница 24: ...st measuring point M1 top side of bearing housing vertical vibration 2 Place the measuring point on the second meas uring point M2 laterally on the bearing housing horizontal vibration 3 The measured...

Страница 25: ...risk of fatal injury from electric shock when working on electrical devices With all maintenance or repair work the motor must be disconnected from the mains by a qualified electrician and secured aga...

Страница 26: ...de for sealing chamber monitoring if applicable Oil change in the sealing chamber Check the leakage chamber for leaks NOTICE If sealing chamber monitoring is installed the maintenance interval corresp...

Страница 27: ...ent temperature and the electrical connection for the pencil electrode has to be disconnected in the switchgear The monitoring device can then be checked with an ohmmeter The following values should b...

Страница 28: ...runs freely again 2 The sealing chamber monitoring optional has interrupted the electric circuit operator related See fault Mechanical seal leak sealing chamber monitoring reports a fault or shuts dow...

Страница 29: ...defective Replace the mechanical seal and contact the plant Further steps for troubleshooting If the points listed here do not rectify the fault contact the Wilo customer service They can help you as...

Страница 30: ......

Страница 31: ......

Страница 32: ...Pioneering for You WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com Local contact at www wilo com contact...

Отзывы: