8.2 Filling and venting

Only a completely filled pump without air inclusions 
can draw in fluid optimally. Perform filling and vent-
ing as follows:

a) Pump with inlet pressure (Fig.

 

3b)

• Close stop valve on the pressure side (Fig.

 

3b, 

item

 

12)

• Loosen the screw plug for filling/venting (Fig. 1 

or 2, item 2).

• Slightly open stop valve on the inlet side (Fig.

 

3b, 

item

 

11), until water emerges from the filler open-

ing and the pump is completely vented.

WARNING!
There is a risk of scalding! Depending on the 
temperature of the fluid and system pressure, 
hot liquid or gaseous fluid may escape or shoot 
out at high pressure when the vent plug is 
opened completely.

• Screw the screw plug back in tightly when the 

water emerges free from bubbles.

• Open the stop valve on the pressure side 

(Fig.

 

3b, item

 

12).

• Continue commissioning with the pressure 

switch setting.

b) Self-priming pump in suction mode (Fig.

 

3c) 

(maximum suction head 8 m)
• Open shut-off device on the pressure side 

(Fig.

 

3c, item

 

12).

• Open shut-off device on the suction side 

(Fig.

 

3c, item

 

11).

• Remove the screw plug for filling/venting (Fig. 1 

or 2, item 2).

• Using a funnel, slowly and completely fill the 

pump at the filler opening, until water emerges 
from the opening (Fig. 3c).

• Screw the screw plug back in tightly when the 

water emerges free from bubbles.

• Continue commissioning with the pressure 

switch setting.

WARNING!
The entire system can get very hot, depending 
on the operating status of the domestic water 
system (temperature of the fluid) Risk of burns 
on contact!

NOTE:
The pump is not allowed to be operated for more 
than 10 minutes with volume flow Q = 0 m

3

/h 

(closed stop valve).

c) Self-priming pump in suction mode (Fig.

 

3c) 

(maximum suction head 7

 

m)

• Open shut-off device on the pressure side 

(Fig.

 

3c, item

 

12).

• Open shut-off device on the suction side 

(Fig.

 

3c, item

 

11).

• Remove the screw plug for filling/venting (Fig. 1 

and 2, item 2).

• Using a funnel, slowly and completely fill the 

pump at the filler opening, until water emerges 
from the opening.

• Screw the screw plug back in tightly when the 

water emerges free from bubbles.

• Start the domestic water system for a short 

period (approx. 20

 

sec.) so that the air will col-

lect in the pump housing. 

• Switch off the domestic water system.
• Repeat the filling procedure until the pump and 

inlet pipe have been completely vented. 

• Continue commissioning with the pressure 

switch setting.

WARNING! 
The entire system can get very hot, depending 
on the operating status of the domestic water 
system (temperature of the fluid). Risk of burns 
on contact!

NOTE:
The pump is not allowed to be operated for more 
than 10 minutes with volume flow Q = 0 m

3

/h 

(closed stop valve).

8.3 Setting the pressure switch

NOTE:
The switch-on and switch-off pressures of the 
pressure switch have been factory-set according 
to the pump curve of the pump used (see rating 
plate).
To adapt to local conditions, it is possible to 
change or adapt the settings of the pressure 
switch as follows.
The switch-off pressure (adjusting screw  
Fig.

 

6a/6b or 6c/6d, item

 

a) and the pressure dif-

ference (adjusting screw Fig.

 

6a/6b or 6c/6d, 

item

 

b) are set in relation to the switch-on pres-

sure at the pressure switch (EM version). 
The switch-off pressure (adjusting screw  
Fig.

 

7a/7b, item

 

a) and the pressure difference 

(adjusting screw Fig.

 

7a/7b, item

 

b) are set in rela-

tion to the switch-on pressure at the pressure 
switch (DM version). 

The following diagram describes the procedure for 
setting the pressure switches.

Содержание Wilo-HiMulti 3 H Series

Страница 1: ...MHI Wilo Jet HWJ Pioneering for You 2 544 452 Ed 01 2016 01 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bedi...

Страница 2: ...Fig 1 L2 L2 P1 P1 8 2 7 1 4 9 5 6 3 Fig 2 L2 L2 P1 P1 8 2 3 7 1 4 9 5 6...

Страница 3: ...Fig 3a min 500mm 1 230V 50Hz min 300mm HC HR 10 14 14 11 12 6 16...

Страница 4: ...Fig 3b 1 230V 50Hz min 300mm HR 14 11 14 13 12 14 6 11 15...

Страница 5: ...Fig 3c 1 230V 50Hz min 1000mm HR HA 16 11 14 14 12 6 10...

Страница 6: ...Fig 4 OK Fig 5a...

Страница 7: ...Fig 5b OK Fig 6a Fig 6b a e b c d a b e c d h i BN BU GNYE BN BU GNYE WJ Jetson MHI Multi H...

Страница 8: ...Fig 6c Fig 6d a b c e h i d BN BU L N GNYE HiMulti3 Claris Home BN BN BU BU GNYE GNYE PE N L Fig 7a Fig 7b a e b c d a b e k j d c BK BN BU BN BK BU GNYE BK BN BU GNYE BK BN BU GNYE BK BN BU GNYE...

Страница 9: ...Fig 8a Fig 8b pe bar pa bar pe bar pa bar Fig 9a Fig 9b Fig 9c...

Страница 10: ...Fig 10a 16 19 19 18 19 17 19 7 BN BN BK BN BU BU BU GNYE BK BN BN BU BU GNYE BK BN BN BU BU GNYE Fig 10b 16 20 7 BN BN BK BU BN BU BU GNYE BK BK BK BN BU 19 19...

Страница 11: ...re parts 22 2 8 Improper use 22 3 Transport and interim storage 22 4 Application intended use 22 5 Product information 23 5 1 Type key 23 5 2 Technical data 23 5 3 Scope of delivery 24 5 4 Accessories...

Страница 12: ...itch off pressure b Adjusting screw for pressure difference switch on pressure c Motor cables connections d Network supply line connections e Earthing connections PE h Motor connection diagram WJ EM i...

Страница 13: ...M 19 Additional connection terminals Cable colours BN Brown BU Blue BK Black GNYE Green Yellow Fig 10b HiMulti3 connection diagram for optional float switch low water cut out switch 7 Pressure switch...

Страница 14: ...e is a risk of damaging the product unit Caution implies that damage to the product is likely if this information is disregarded NOTE Useful information on handling the product It draws attention to p...

Страница 15: ...other parts will absolve us of liability for consequential events 2 8 Improper use The operating safety of the supplied product is only guaranteed for conventional use in accord ance with section 4 of...

Страница 16: ...e sep arateinstallationandoperatinginstruc tions and rating plate for the pump 6 8 10 bar Volume of the dia phragm pressure vessel See rating plate Gas supply pres sure for diaphragm pressure vessel S...

Страница 17: ...the pressure in the consumer line When water is extracted the pressure in the consumer line drops When the switch on pres sure set on the pressure switch is reached the domestic water system is switc...

Страница 18: ...3c This must be installed contin uously rising from the tank to the pump connec tion on the suction side The foot valve shall be positioned so as to achieve a distance of 100 mm from the base of the...

Страница 19: ...must be filled with water before start ing the domestic water system section 8 2 8 1 Check the diaphragm pressure vessel In order for the domestic water system to operate correctly it is necessary to...

Страница 20: ...0 minutes with volume flow Q 0 m3 h closed stop valve c Self priming pump in suction mode Fig 3c maximum suction head 7 m Open shut off device on the pressure side Fig 3c item 12 Open shut off device...

Страница 21: ...ssure does not match the system parameters Establish electrical power supply and check the settings using the values displayed on the pressure gauge Gas supply pressure of the diaphragm vessel matches...

Страница 22: ...essure difference adjusting screw clockwise until a clicking sound can be heard Remove cover of the pressure switch Shut off electrical power supply and secure it to prevent it from being restarted wi...

Страница 23: ...pressure on the pres sure gauge When the domestic water system starts again ensure that the current consumption does not exceed the rated current 8 6 Decommissioning CAUTION Risk of damage to the dome...

Страница 24: ...mp Dry running protection tripped water level too low Check water level and correct Pump defective Replace pump Pump is running but not pumping Incorrect direction of rotation DM version Swap 2 phases...

Страница 25: ...rt after cooling down Geodesic head 1000 m Pump is only approved for geodesic head 1000 m Motor protection DMversion is set too low Adjust setting of motor protection to rated motor current One phase...

Страница 26: ...English Installation and operating instructions Wilo domestic water systems HiMulti3 H HMHI HWJ 33...

Страница 27: ......

Страница 28: ...HJUDWH 0 7 ZLOR LWDOLD ZLOR LW D DNKVWDQ 2 HQWUDO VLD OPDW 7 LQIR ZLOR N RUHD 2 3XPSV WG DQJVHR XVDQ 7 ZLOR ZLOR FR NU DWYLD 2 DOWLF 6 5LJD 7 LQIR ZLOR OY HEDQRQ 2 121 6 5 GHLGHK HEDQRQ 7 LQIR ZLOR FR...

Страница 29: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: