8.2 Filling and venting
Only a completely filled pump without air inclusions
can draw in fluid optimally. Perform filling and vent-
ing as follows:
a) Pump with inlet pressure (Fig.
3b)
• Close stop valve on the pressure side (Fig.
3b,
item
12)
• Loosen the screw plug for filling/venting (Fig. 1
or 2, item 2).
• Slightly open stop valve on the inlet side (Fig.
3b,
item
11), until water emerges from the filler open-
ing and the pump is completely vented.
WARNING!
There is a risk of scalding! Depending on the
temperature of the fluid and system pressure,
hot liquid or gaseous fluid may escape or shoot
out at high pressure when the vent plug is
opened completely.
• Screw the screw plug back in tightly when the
water emerges free from bubbles.
• Open the stop valve on the pressure side
(Fig.
3b, item
12).
• Continue commissioning with the pressure
switch setting.
b) Self-priming pump in suction mode (Fig.
3c)
(maximum suction head 8 m)
• Open shut-off device on the pressure side
(Fig.
3c, item
12).
• Open shut-off device on the suction side
(Fig.
3c, item
11).
• Remove the screw plug for filling/venting (Fig. 1
or 2, item 2).
• Using a funnel, slowly and completely fill the
pump at the filler opening, until water emerges
from the opening (Fig. 3c).
• Screw the screw plug back in tightly when the
water emerges free from bubbles.
• Continue commissioning with the pressure
switch setting.
WARNING!
The entire system can get very hot, depending
on the operating status of the domestic water
system (temperature of the fluid) Risk of burns
on contact!
NOTE:
The pump is not allowed to be operated for more
than 10 minutes with volume flow Q = 0 m
3
/h
(closed stop valve).
c) Self-priming pump in suction mode (Fig.
3c)
(maximum suction head 7
m)
• Open shut-off device on the pressure side
(Fig.
3c, item
12).
• Open shut-off device on the suction side
(Fig.
3c, item
11).
• Remove the screw plug for filling/venting (Fig. 1
and 2, item 2).
• Using a funnel, slowly and completely fill the
pump at the filler opening, until water emerges
from the opening.
• Screw the screw plug back in tightly when the
water emerges free from bubbles.
• Start the domestic water system for a short
period (approx. 20
sec.) so that the air will col-
lect in the pump housing.
• Switch off the domestic water system.
• Repeat the filling procedure until the pump and
inlet pipe have been completely vented.
• Continue commissioning with the pressure
switch setting.
WARNING!
The entire system can get very hot, depending
on the operating status of the domestic water
system (temperature of the fluid). Risk of burns
on contact!
NOTE:
The pump is not allowed to be operated for more
than 10 minutes with volume flow Q = 0 m
3
/h
(closed stop valve).
8.3 Setting the pressure switch
NOTE:
The switch-on and switch-off pressures of the
pressure switch have been factory-set according
to the pump curve of the pump used (see rating
plate).
To adapt to local conditions, it is possible to
change or adapt the settings of the pressure
switch as follows.
The switch-off pressure (adjusting screw
Fig.
6a/6b or 6c/6d, item
a) and the pressure dif-
ference (adjusting screw Fig.
6a/6b or 6c/6d,
item
b) are set in relation to the switch-on pres-
sure at the pressure switch (EM version).
The switch-off pressure (adjusting screw
Fig.
7a/7b, item
a) and the pressure difference
(adjusting screw Fig.
7a/7b, item
b) are set in rela-
tion to the switch-on pressure at the pressure
switch (DM version).
The following diagram describes the procedure for
setting the pressure switches.
Содержание Wilo-HiMulti 3 H Series
Страница 2: ...Fig 1 L2 L2 P1 P1 8 2 7 1 4 9 5 6 3 Fig 2 L2 L2 P1 P1 8 2 3 7 1 4 9 5 6...
Страница 3: ...Fig 3a min 500mm 1 230V 50Hz min 300mm HC HR 10 14 14 11 12 6 16...
Страница 4: ...Fig 3b 1 230V 50Hz min 300mm HR 14 11 14 13 12 14 6 11 15...
Страница 5: ...Fig 3c 1 230V 50Hz min 1000mm HR HA 16 11 14 14 12 6 10...
Страница 6: ...Fig 4 OK Fig 5a...
Страница 7: ...Fig 5b OK Fig 6a Fig 6b a e b c d a b e c d h i BN BU GNYE BN BU GNYE WJ Jetson MHI Multi H...
Страница 9: ...Fig 8a Fig 8b pe bar pa bar pe bar pa bar Fig 9a Fig 9b Fig 9c...
Страница 26: ...English Installation and operating instructions Wilo domestic water systems HiMulti3 H HMHI HWJ 33...
Страница 27: ......