If hot or cold components on the product/unit lead 

to hazards, local measures must be taken to guard 
these components against touching.

• Guards protecting against touching moving com-

ponents (such as the coupling) must not be 
removed whilst the product is in operation. 

• Leakages (e.g. from a shaft seal) of hazardous flu-

ids (e.g. explosive, toxic or hot) must be conveyed 
away so that no danger to persons or to the envi-
ronment arises. National statutory provisions are 
to be complied with. 

• Highly flammable materials are always to be kept 

at a safe distance from the product.

• Danger from electrical current must be eliminated. 

Local directives or general directives (e.g. IEC, VDE 
etc.) and instructions from local energy supply com-
panies must be adhered to.

2.6 Safety instructions for inspection and 

installation work

The operator must ensure that all installation and 
maintenance work is carried out by authorised and 
qualified personnel, who are sufficiently informed 
from their own detailed study of the installation 
and operating instructions.
Work on the product/unit must only be carried out 
when at a standstill. It is mandatory that the pro-
cedure described in the installation and operating 
instructions for shutting down the product/unit 
be complied with.
Immediately on conclusion of the work, all safety 
and protective devices must be put back in posi-
tion and/or recommissioned.

2.7 Unauthorised modification and manufacture of 

spare parts

Unauthorised modification and manufacture of 
spare parts will impair the safety of the product/
personnel and will make void the manufacturer’s 
declarations regarding safety.
Modifications to the product are only permissible 
after consultation with the manufacturer. Original 
spare parts and accessories authorised by the 
manufacturer ensure safety. The use of other 
parts will absolve us of liability for consequential 
events.

2.8 Improper use

The operating safety of the supplied product is 
only guaranteed for conventional use in accord-
ance with section 4 of the operating instructions. 
The limit values must on no account fall under or 
exceed those values specified in the catalogue/
data sheet.

3 Transport and interim storage

When you receive the domestic water system, 
immediately check it for transport damage. If you 
discover transport damage, discuss with the cou-
rier company what measures to take, complying 
with the relevant notification deadlines!

CAUTION! Risk of property damage!
Incorrect transport and interim storage can 
cause damage to the product.

The domestic water system should be protected 
from moisture, frost and mechanical damage due 
to impact during transport and interim storage.
The domestic water system must never be exposed 
to temperatures outside the range - 10 °C to + 50 °C 
during transport or storage.

4 Application (intended use)

Domestic water systems are designed to pump 
rain and process water and serve to pump water 
from tanks, ponds, streams and wells for water 
supply, irrigation, sprinkling and spraying in 
domestic applications. 

A direct connection to the public drinking water net-
work for drinking water supply is not permissible.

Non-self-priming or self-priming pumps are used, 
depending on the application. 

Non-self-priming pumps (HiMulti3; MHI) must run 
in inlet mode (e.g. higher tank Fig. 3a or mains  
Fig. 3b), as they are not capable of evacuating air 
from the inlet pipe.
Self-priming pumps (HiMulti3-P; WJ) can evacuate 
air from the inlet pipe via air extraction technology. 
As a result, they are suitable for pumping from ves-
sels in lower positions (e.g. from a well or cistern).

Permitted fluids:

• Water without any solids or settling sediments 

(process water, refrigerating water, cooling water 
and rainwater)
Use with other fluids or additives requires 
approval from Wilo.

DANGER! 
Risk of explosion! This domestic water system 
must not be used to pump flammable or explo-
sive fluids.

Содержание Wilo-HiMulti 3 H Series

Страница 1: ...MHI Wilo Jet HWJ Pioneering for You 2 544 452 Ed 01 2016 01 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bedi...

Страница 2: ...Fig 1 L2 L2 P1 P1 8 2 7 1 4 9 5 6 3 Fig 2 L2 L2 P1 P1 8 2 3 7 1 4 9 5 6...

Страница 3: ...Fig 3a min 500mm 1 230V 50Hz min 300mm HC HR 10 14 14 11 12 6 16...

Страница 4: ...Fig 3b 1 230V 50Hz min 300mm HR 14 11 14 13 12 14 6 11 15...

Страница 5: ...Fig 3c 1 230V 50Hz min 1000mm HR HA 16 11 14 14 12 6 10...

Страница 6: ...Fig 4 OK Fig 5a...

Страница 7: ...Fig 5b OK Fig 6a Fig 6b a e b c d a b e c d h i BN BU GNYE BN BU GNYE WJ Jetson MHI Multi H...

Страница 8: ...Fig 6c Fig 6d a b c e h i d BN BU L N GNYE HiMulti3 Claris Home BN BN BU BU GNYE GNYE PE N L Fig 7a Fig 7b a e b c d a b e k j d c BK BN BU BN BK BU GNYE BK BN BU GNYE BK BN BU GNYE BK BN BU GNYE...

Страница 9: ...Fig 8a Fig 8b pe bar pa bar pe bar pa bar Fig 9a Fig 9b Fig 9c...

Страница 10: ...Fig 10a 16 19 19 18 19 17 19 7 BN BN BK BN BU BU BU GNYE BK BN BN BU BU GNYE BK BN BN BU BU GNYE Fig 10b 16 20 7 BN BN BK BU BN BU BU GNYE BK BK BK BN BU 19 19...

Страница 11: ...re parts 22 2 8 Improper use 22 3 Transport and interim storage 22 4 Application intended use 22 5 Product information 23 5 1 Type key 23 5 2 Technical data 23 5 3 Scope of delivery 24 5 4 Accessories...

Страница 12: ...itch off pressure b Adjusting screw for pressure difference switch on pressure c Motor cables connections d Network supply line connections e Earthing connections PE h Motor connection diagram WJ EM i...

Страница 13: ...M 19 Additional connection terminals Cable colours BN Brown BU Blue BK Black GNYE Green Yellow Fig 10b HiMulti3 connection diagram for optional float switch low water cut out switch 7 Pressure switch...

Страница 14: ...e is a risk of damaging the product unit Caution implies that damage to the product is likely if this information is disregarded NOTE Useful information on handling the product It draws attention to p...

Страница 15: ...other parts will absolve us of liability for consequential events 2 8 Improper use The operating safety of the supplied product is only guaranteed for conventional use in accord ance with section 4 of...

Страница 16: ...e sep arateinstallationandoperatinginstruc tions and rating plate for the pump 6 8 10 bar Volume of the dia phragm pressure vessel See rating plate Gas supply pres sure for diaphragm pressure vessel S...

Страница 17: ...the pressure in the consumer line When water is extracted the pressure in the consumer line drops When the switch on pres sure set on the pressure switch is reached the domestic water system is switc...

Страница 18: ...3c This must be installed contin uously rising from the tank to the pump connec tion on the suction side The foot valve shall be positioned so as to achieve a distance of 100 mm from the base of the...

Страница 19: ...must be filled with water before start ing the domestic water system section 8 2 8 1 Check the diaphragm pressure vessel In order for the domestic water system to operate correctly it is necessary to...

Страница 20: ...0 minutes with volume flow Q 0 m3 h closed stop valve c Self priming pump in suction mode Fig 3c maximum suction head 7 m Open shut off device on the pressure side Fig 3c item 12 Open shut off device...

Страница 21: ...ssure does not match the system parameters Establish electrical power supply and check the settings using the values displayed on the pressure gauge Gas supply pressure of the diaphragm vessel matches...

Страница 22: ...essure difference adjusting screw clockwise until a clicking sound can be heard Remove cover of the pressure switch Shut off electrical power supply and secure it to prevent it from being restarted wi...

Страница 23: ...pressure on the pres sure gauge When the domestic water system starts again ensure that the current consumption does not exceed the rated current 8 6 Decommissioning CAUTION Risk of damage to the dome...

Страница 24: ...mp Dry running protection tripped water level too low Check water level and correct Pump defective Replace pump Pump is running but not pumping Incorrect direction of rotation DM version Swap 2 phases...

Страница 25: ...rt after cooling down Geodesic head 1000 m Pump is only approved for geodesic head 1000 m Motor protection DMversion is set too low Adjust setting of motor protection to rated motor current One phase...

Страница 26: ...English Installation and operating instructions Wilo domestic water systems HiMulti3 H HMHI HWJ 33...

Страница 27: ......

Страница 28: ...HJUDWH 0 7 ZLOR LWDOLD ZLOR LW D DNKVWDQ 2 HQWUDO VLD OPDW 7 LQIR ZLOR N RUHD 2 3XPSV WG DQJVHR XVDQ 7 ZLOR ZLOR FR NU DWYLD 2 DOWLF 6 5LJD 7 LQIR ZLOR OY HEDQRQ 2 121 6 5 GHLGHK HEDQRQ 7 LQIR ZLOR FR...

Страница 29: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: