30

WILO SE 01/2016 

8.4 Checking the direction of rotation of the motor

EM version:

 Switch on briefly and verify that the 

direction of rotation of the pumps (look at the fan 
wheel of the motor) corresponds to the direction 
of the arrow on the pump’s rating plate. The sin-
gle-phase motors used are designed specifically 
for the necessary direction of rotation of the 
respective pump. The direction of rotation cannot 
be changed. If the direction of rotation is incorrect 
in spite of this, the pump must be handed to the 
Wilo customer service for checks and repairs.

DM version: 

Switch on briefly and verify that the 

direction of rotation of the pumps (look at the fan 
wheel of the motor) corresponds to the direction 
of the arrow on the pump’s rating plate. If the 
direction of rotation is wrong, disconnect the 
domestic water system from the power supply and 
swap over 2 phases in the terminal box of the 
pump.

DANGER!
Risk of fatal injury! Electrical connection must 
be carried out by an electrician authorised by 
the local electricity supply company and in 
accordance with the applicable local regulations 
(e.g. VDE regulations).

8.5 Commissioning

After completing all installation and setting work, 
the domestic water system can be commissioned 
as follows:

• Open shut-off device on the pressure side and 

open an outlet valve (consumer).

• Open the shut-off device on the suction side.
• Connect the domestic water system to the power 

supply.

• Self-priming pumps can take a few minutes to 

start up if the suction pipe is not completely full of 
water (leave the outlet valve open).

CAUTION!
The pump must not be allowed to operate with-
out flow for more than 10 minutes (outlet valve 
closed).
WARNING! Risk of scalding!
If operated without flow, the water temperature 
rises.

• To avoid air pockets forming, we recommend a 

minimum flow of 15% of the pump throughput. 

• If no water comes out of the outlet valve after  

3 minutes, stop the domestic water system and 
repeat the filling process.

• After the pump has started and sufficient water 

comes out of the outlet valve, close the outlet 
valve fully and check whether the domestic water 
system switches off when the switch-off pressure 
set is reached.

• Check the system for leakages (visual inspection 

for leakages and check the pressure on the pres-
sure gauge).

• When the domestic water system starts again, 

ensure that the current consumption does not 
exceed the rated current.

8.6 Decommissioning

CAUTION!
Risk of damage to the domestic water system!  
If there is a risk of frost, the system must be  
completely drained.

Prior to a long standstill (e.g. overwintering), the 
domestic water system must be thoroughly flushed 
through, completely drained and then stored in a 
dry place.

• Disconnect the domestic water system from the 

mains. 

• Close the inlet side shut-off device (Fig. 3a, 3b  

or 3c, item 11).

• Depressurise the consumer line by opening an 

extraction valve.

• Drain the pump via the drainage screw (Fig. 1 and 2, 

item 3).

• Drain the domestic water system fully be loosening 

the screwed connection of the flexible pressure hose 
(Figs. 1 and 2, item 8) on the tank connection.

• Disconnect the domestic water system from the 

supply piping and piping on the pressure side and 
store it in a dry place.
Before recommissioning the system, check that 
the pump shaft can turn freely (e.g. by turning the 
fan wheel manually).

9 Maintenance

WARNING! Electrical hazard!
Before conducting the check, disconnect the 
domestic water system from the mains and 
secure it to prevent it from being switched back 
on inadvertently.

The main components of WILO domestic water 
systems are almost maintenance-free. The fol-
lowing checks are recommended at 3-monthly 
intervals in order to guarantee the highest opera-
tional reliability with the lowest possible operat-
ing costs:

• Check the diaphragm pressure vessel has the gas 

supply pressure set correctly (Fig.

 

9a to 9c). To do 

so, disconnect the domestic water system from 
the mains and depressurise the tank (close the 
shut-off device on the suction side (Figs. 3a to 3c, 
item 11), open the outlet fitting on the pressure 
side until the pressure gauge (Figs. 1 and 2, item 5) 
shows 0 bar.

WARNING! Risk of suffocation by nitrogen! 
Measuring, replenishing and venting of nitrogen 
at the diaphragm pressure vessel is only allowed 
to be performed by qualified specialist person-
nel.
WARNING! Risk of injury!
Excessive pressure can cause the container to 
rupture and lead to serious injuries! Monitor the 
gas supply pressure by measuring during the 
filling procedure. When measuring instruments 
with different scale divisions (unit of dimension) 
are used, it is essential to comply with the 
instructions for converting!
Comply with the general safety regulations for 
working with pressure vessels.

Содержание Wilo-HiMulti 3 H Series

Страница 1: ...MHI Wilo Jet HWJ Pioneering for You 2 544 452 Ed 01 2016 01 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bedi...

Страница 2: ...Fig 1 L2 L2 P1 P1 8 2 7 1 4 9 5 6 3 Fig 2 L2 L2 P1 P1 8 2 3 7 1 4 9 5 6...

Страница 3: ...Fig 3a min 500mm 1 230V 50Hz min 300mm HC HR 10 14 14 11 12 6 16...

Страница 4: ...Fig 3b 1 230V 50Hz min 300mm HR 14 11 14 13 12 14 6 11 15...

Страница 5: ...Fig 3c 1 230V 50Hz min 1000mm HR HA 16 11 14 14 12 6 10...

Страница 6: ...Fig 4 OK Fig 5a...

Страница 7: ...Fig 5b OK Fig 6a Fig 6b a e b c d a b e c d h i BN BU GNYE BN BU GNYE WJ Jetson MHI Multi H...

Страница 8: ...Fig 6c Fig 6d a b c e h i d BN BU L N GNYE HiMulti3 Claris Home BN BN BU BU GNYE GNYE PE N L Fig 7a Fig 7b a e b c d a b e k j d c BK BN BU BN BK BU GNYE BK BN BU GNYE BK BN BU GNYE BK BN BU GNYE...

Страница 9: ...Fig 8a Fig 8b pe bar pa bar pe bar pa bar Fig 9a Fig 9b Fig 9c...

Страница 10: ...Fig 10a 16 19 19 18 19 17 19 7 BN BN BK BN BU BU BU GNYE BK BN BN BU BU GNYE BK BN BN BU BU GNYE Fig 10b 16 20 7 BN BN BK BU BN BU BU GNYE BK BK BK BN BU 19 19...

Страница 11: ...re parts 22 2 8 Improper use 22 3 Transport and interim storage 22 4 Application intended use 22 5 Product information 23 5 1 Type key 23 5 2 Technical data 23 5 3 Scope of delivery 24 5 4 Accessories...

Страница 12: ...itch off pressure b Adjusting screw for pressure difference switch on pressure c Motor cables connections d Network supply line connections e Earthing connections PE h Motor connection diagram WJ EM i...

Страница 13: ...M 19 Additional connection terminals Cable colours BN Brown BU Blue BK Black GNYE Green Yellow Fig 10b HiMulti3 connection diagram for optional float switch low water cut out switch 7 Pressure switch...

Страница 14: ...e is a risk of damaging the product unit Caution implies that damage to the product is likely if this information is disregarded NOTE Useful information on handling the product It draws attention to p...

Страница 15: ...other parts will absolve us of liability for consequential events 2 8 Improper use The operating safety of the supplied product is only guaranteed for conventional use in accord ance with section 4 of...

Страница 16: ...e sep arateinstallationandoperatinginstruc tions and rating plate for the pump 6 8 10 bar Volume of the dia phragm pressure vessel See rating plate Gas supply pres sure for diaphragm pressure vessel S...

Страница 17: ...the pressure in the consumer line When water is extracted the pressure in the consumer line drops When the switch on pres sure set on the pressure switch is reached the domestic water system is switc...

Страница 18: ...3c This must be installed contin uously rising from the tank to the pump connec tion on the suction side The foot valve shall be positioned so as to achieve a distance of 100 mm from the base of the...

Страница 19: ...must be filled with water before start ing the domestic water system section 8 2 8 1 Check the diaphragm pressure vessel In order for the domestic water system to operate correctly it is necessary to...

Страница 20: ...0 minutes with volume flow Q 0 m3 h closed stop valve c Self priming pump in suction mode Fig 3c maximum suction head 7 m Open shut off device on the pressure side Fig 3c item 12 Open shut off device...

Страница 21: ...ssure does not match the system parameters Establish electrical power supply and check the settings using the values displayed on the pressure gauge Gas supply pressure of the diaphragm vessel matches...

Страница 22: ...essure difference adjusting screw clockwise until a clicking sound can be heard Remove cover of the pressure switch Shut off electrical power supply and secure it to prevent it from being restarted wi...

Страница 23: ...pressure on the pres sure gauge When the domestic water system starts again ensure that the current consumption does not exceed the rated current 8 6 Decommissioning CAUTION Risk of damage to the dome...

Страница 24: ...mp Dry running protection tripped water level too low Check water level and correct Pump defective Replace pump Pump is running but not pumping Incorrect direction of rotation DM version Swap 2 phases...

Страница 25: ...rt after cooling down Geodesic head 1000 m Pump is only approved for geodesic head 1000 m Motor protection DMversion is set too low Adjust setting of motor protection to rated motor current One phase...

Страница 26: ...English Installation and operating instructions Wilo domestic water systems HiMulti3 H HMHI HWJ 33...

Страница 27: ......

Страница 28: ...HJUDWH 0 7 ZLOR LWDOLD ZLOR LW D DNKVWDQ 2 HQWUDO VLD OPDW 7 LQIR ZLOR N RUHD 2 3XPSV WG DQJVHR XVDQ 7 ZLOR ZLOR FR NU DWYLD 2 DOWLF 6 5LJD 7 LQIR ZLOR OY HEDQRQ 2 121 6 5 GHLGHK HEDQRQ 7 LQIR ZLOR FR...

Страница 29: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: