5 Product information

5.1 Type key

Example: HiMulti3H50-24P

HiMulti3

Pump type

= Wilo-HiMulti3

H

D

omestic water system

20

50

100

Tank volume
= 20-litre tank 
= 50-litre tank
= 100-litre tank

2

4

= Rated volume flow Q in m³/h at optimum 
efficiency

3

4

5

= Number of stages

հ

P

Pump type
= Non-self-priming pump  
(no designation)
= Self-priming pump

Example: HWJ-204-EM-50

H

= Domestic water system with pump

WJ

Pump type

= Wilo-Jet

2

= Rated volume flow Q in m³/h at optimum 
efficiency

02
03

04

Power classification of motor P1 (in W)
= 890

 

W

= 1100

 

W

= 1300

 

W

EM

DM

= Alternating current 1~230

 

V

= Three-phase current 3 ~ 400

 

V

հ

50

= 20-litre tank  
(no additional designation)
= 50-litre tank

Example: HMHI-403-EM

H

= Domestic water system with pump

MHI

Pump type

= Wilo-Economy MHI

2

4

= Rated volume flow Q in m³/h at optimum 
efficiency

02

03

04
05
06

= Number of stages

EM

DM

= Alternating current 1~230

 

V

= Three-phase current 3 ~ 400

 

V

5.2 Technical data

For the precise connection and technical data, please 
refer to the rating plates on the pump and the motor.

Connection and technical data

Hydraulic data

Delivery head

See rating plate

Volume flow

See rating plate

Switch-on/switch-
off pressure

See rating plate

Maximum operat-
ing pressure

Depending on the pump type (see sep-
arate installation and operating instruc-
tions and rating plate for the pump)
6/8/10 bar

Volume of the dia-
phragm pressure 
vessel

See rating plate

Gas supply pres-
sure for diaphragm 
pressure vessel

See rating plate and Table 1

Maximum height 
above sea level

1000

 

m

Suction head

Depending on the pump type / depend-
ing on NPSH (see separate installation 
and operating instructions for the pump)

Suction connec-
tion

HiMulti3-…

WJ 2..
MHI 2..
MHI 4…

Depending on the pump type (see 
separate installation and operating 
instructions for the pump)
G1 (female thread)

DIN ISO

 

228 T1

Adapter with male thread on both sides 
in the accessories kit
G1 (female thread)

DIN ISO

 

228 T1

G1 (female thread)

DIN ISO

 

228 T1

G1

¼

 (female thread)

DIN ISO

 

228 T1

Pressure connection

Rp1 (female thread DIN 2999 or ISO

 

7/1)

Temperature range

Temperature of the 
fluid

+ 5 °C to + 35 °C

Max. ambient tem-
perature 

+ 40 °C

Electrical data

Mains connection

See rating plate of pump/motor
1~230 V/50

 

Hz

1~220 V/60

 

Hz 

3~230/400

 

V/50

 

Hz

3~220/380

 

V  

up to 3~254/440

 

V/60

 

Hz

Protection class

IPX4 (see the installation and operat-
ing instructions for the pump)

Motor insulation 
class

F (155 °C) (see the installation and 
operating instructions for the pump)

Weight

See rating plate

Dimensions, other

Distances between 
holes for attachment
L2 x P1 
(Fig. 1 and 2)

20 litre tank 

Ô

 170 x 230

 

mm

50 litre tank 

Ô

 235 x 253

 

mm

100 litre tank 

Ô

 310 x 248

 

mm

Fastening screws required 4 x Ø8

 

mm (20

 

L and 100

 

L tank) 

or 4 x Ø6

 

mm (50

 

L tank)

See dimension drawing/catalogue/data sheet for further 
dimensions

Содержание Wilo-HiMulti 3 H Series

Страница 1: ...MHI Wilo Jet HWJ Pioneering for You 2 544 452 Ed 01 2016 01 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bedi...

Страница 2: ...Fig 1 L2 L2 P1 P1 8 2 7 1 4 9 5 6 3 Fig 2 L2 L2 P1 P1 8 2 3 7 1 4 9 5 6...

Страница 3: ...Fig 3a min 500mm 1 230V 50Hz min 300mm HC HR 10 14 14 11 12 6 16...

Страница 4: ...Fig 3b 1 230V 50Hz min 300mm HR 14 11 14 13 12 14 6 11 15...

Страница 5: ...Fig 3c 1 230V 50Hz min 1000mm HR HA 16 11 14 14 12 6 10...

Страница 6: ...Fig 4 OK Fig 5a...

Страница 7: ...Fig 5b OK Fig 6a Fig 6b a e b c d a b e c d h i BN BU GNYE BN BU GNYE WJ Jetson MHI Multi H...

Страница 8: ...Fig 6c Fig 6d a b c e h i d BN BU L N GNYE HiMulti3 Claris Home BN BN BU BU GNYE GNYE PE N L Fig 7a Fig 7b a e b c d a b e k j d c BK BN BU BN BK BU GNYE BK BN BU GNYE BK BN BU GNYE BK BN BU GNYE...

Страница 9: ...Fig 8a Fig 8b pe bar pa bar pe bar pa bar Fig 9a Fig 9b Fig 9c...

Страница 10: ...Fig 10a 16 19 19 18 19 17 19 7 BN BN BK BN BU BU BU GNYE BK BN BN BU BU GNYE BK BN BN BU BU GNYE Fig 10b 16 20 7 BN BN BK BU BN BU BU GNYE BK BK BK BN BU 19 19...

Страница 11: ...re parts 22 2 8 Improper use 22 3 Transport and interim storage 22 4 Application intended use 22 5 Product information 23 5 1 Type key 23 5 2 Technical data 23 5 3 Scope of delivery 24 5 4 Accessories...

Страница 12: ...itch off pressure b Adjusting screw for pressure difference switch on pressure c Motor cables connections d Network supply line connections e Earthing connections PE h Motor connection diagram WJ EM i...

Страница 13: ...M 19 Additional connection terminals Cable colours BN Brown BU Blue BK Black GNYE Green Yellow Fig 10b HiMulti3 connection diagram for optional float switch low water cut out switch 7 Pressure switch...

Страница 14: ...e is a risk of damaging the product unit Caution implies that damage to the product is likely if this information is disregarded NOTE Useful information on handling the product It draws attention to p...

Страница 15: ...other parts will absolve us of liability for consequential events 2 8 Improper use The operating safety of the supplied product is only guaranteed for conventional use in accord ance with section 4 of...

Страница 16: ...e sep arateinstallationandoperatinginstruc tions and rating plate for the pump 6 8 10 bar Volume of the dia phragm pressure vessel See rating plate Gas supply pres sure for diaphragm pressure vessel S...

Страница 17: ...the pressure in the consumer line When water is extracted the pressure in the consumer line drops When the switch on pres sure set on the pressure switch is reached the domestic water system is switc...

Страница 18: ...3c This must be installed contin uously rising from the tank to the pump connec tion on the suction side The foot valve shall be positioned so as to achieve a distance of 100 mm from the base of the...

Страница 19: ...must be filled with water before start ing the domestic water system section 8 2 8 1 Check the diaphragm pressure vessel In order for the domestic water system to operate correctly it is necessary to...

Страница 20: ...0 minutes with volume flow Q 0 m3 h closed stop valve c Self priming pump in suction mode Fig 3c maximum suction head 7 m Open shut off device on the pressure side Fig 3c item 12 Open shut off device...

Страница 21: ...ssure does not match the system parameters Establish electrical power supply and check the settings using the values displayed on the pressure gauge Gas supply pressure of the diaphragm vessel matches...

Страница 22: ...essure difference adjusting screw clockwise until a clicking sound can be heard Remove cover of the pressure switch Shut off electrical power supply and secure it to prevent it from being restarted wi...

Страница 23: ...pressure on the pres sure gauge When the domestic water system starts again ensure that the current consumption does not exceed the rated current 8 6 Decommissioning CAUTION Risk of damage to the dome...

Страница 24: ...mp Dry running protection tripped water level too low Check water level and correct Pump defective Replace pump Pump is running but not pumping Incorrect direction of rotation DM version Swap 2 phases...

Страница 25: ...rt after cooling down Geodesic head 1000 m Pump is only approved for geodesic head 1000 m Motor protection DMversion is set too low Adjust setting of motor protection to rated motor current One phase...

Страница 26: ...English Installation and operating instructions Wilo domestic water systems HiMulti3 H HMHI HWJ 33...

Страница 27: ......

Страница 28: ...HJUDWH 0 7 ZLOR LWDOLD ZLOR LW D DNKVWDQ 2 HQWUDO VLD OPDW 7 LQIR ZLOR N RUHD 2 3XPSV WG DQJVHR XVDQ 7 ZLOR ZLOR FR NU DWYLD 2 DOWLF 6 5LJD 7 LQIR ZLOR OY HEDQRQ 2 121 6 5 GHLGHK HEDQRQ 7 LQIR ZLOR FR...

Страница 29: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...