Do not insulate the pump.

Always respect the maintenance and repair 
recommendations for the motor and the pump

.

Respect the installation and commissioning in- 

structions (filling, flushing out...) in order to eli

-

minate any risk of dry running and operation at 

zero delivery rate.

The delivery rate controller supplied with the 

ATEX pump controls the presence of water in the 

upper part of the pump. The electrical connection 

must allow the motor to be switched off in case 
of a lack of water

.

The mechanical seal must be adapted to the  
pumped fluid and to the service conditions

.

To avoid the risk of overspeed, do not exceed the 
pump’s designated capacity

.

The pump must be earthed in compliance with 

the installation instructions.

The operator is responsible for inspecting the 
pump at regular intervals as follows:

•  The hydraulics coupling/motor must always be 

completely tightened to the torque (M6: 8 N·m, 
M8: 22.5 N·m, M10: 45 N·m, M12: 80 N·m) to 

avoid any abnormal play, vibrations and mecha-
nical degradation that may give rise to heat and 

therefore cause sparks.

•  The internal components of the pump must be 

monitored every time maintenance and repair 

work is carried out and replaced if necessary.

•  It is recommended to check that the pump runs 

without any locking point every time the pump is 

stopped for maintenance and repair.

The motor has the ATEX certification. Please refer 
to the respective instructions.

The delivery rate sensor has the ATEX certifica- 

tion. Please refer to the manufacturer’s operating 

instructions and the additional installation and 

operating instructions.

4. 

Installation instructions and  

commissioning of the delivery rate 
controller

Fig. 1

1 - Sensor
2 - Active part of sensor
3 - Delivery rate sensor
4 - Box outside of hazardous area
5 - Delivery rate controller
6 - Air pressure gauge
7 - Pressure connection valve

4.1 

Scope of delivery 

•  Vertical multistage pump 

with its motor.

•  Delivery rate controller, ATEX delivery rate  

sensor

• 

2 connections

•  Teflon band

- Commissioning manual

4.2 

Operating principle of the controller 

Based on thermodynamic principles, the delivery 
rate sensor is heated to a temperature which 
is slightly above that of the fluid in which it is 

submerged. Depending on the delivery rate of 

the fluid, a decrease in its temperature can be 

observed. 

Certificated material 

 II 2G T6 to T3 

(temperature of the liquid 90°C max.)

It is possible to switch off the pump motor if the 

delivery rate is lower than the setpoint. 

 

The pump is thus protected from an increase in 
temperature at a weak delivery rate or at a zero 

delivery rate (with or without fluid).

4.3 

Installation of the detector (Fig. 1)

The sensor shall be assembled in the top part of 

the pump.

Remove the venting plug and use the unions 
provided (if needed) to completely screw the 
active part of the detector (this must be in con-

tact with the liquid).

4.4 

Installation of the delivery rate controller

This device must not be placed in hazardous 

areas. Always follow the manufacturer’s opera

-

ting instructions when connecting the pump.

4.5 

Recommended electrical installation

The motor is supplied with a contactor, a 
time-delayed opening and a normal open con-

tact. There are two push buttons, one for the 
starting up and one for the stopping the pump.

To extend the cable length of the sensor beyond 
a hazardous area, it is recommended to use an 
ATEX cable and connections and accessories 

which are optionally provided.

Self-locking

MA

KM1

KM1

11

13

AT

KM1

Closed contact 

motor contactor

Flow control 

instrument

Push button start

Push button  

stop

Motor contactor 

delay time

(not given)

Open contact 

motor contactor

Содержание Wilo-Helix FIRST V ATEX

Страница 1: ...triebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service es Instrucciones de instalaci n y funcionamiento it Istruzioni di montaggio uso e manutenzione pt...

Страница 2: ...Fig 1 1 2 5 3 4 6 7...

Страница 3: ...7 fr Notice de montage et de mise en service 10 es Instrucciones de instalaci n y funcionamiento 13 it Istruzioni di montaggio uso e manutenzione 16 pt Manual de Instala o e funcionamento 19 ru 22 pl...

Страница 4: ...r der Anlage sodass Explosionsgefahr besteht 2 4 Sicherheitshinweise f r den Betreiber Der Betreiber ist f r die Planung die Montage und den Betrieb des Ger ts unter Einhaltung der geltenden Bestimmun...

Страница 5: ...nleitung und Inbetriebnahme des Durchflussmessers Fig 1 1 Sensor 2 Aktiver Teil des Sensors 3 Volumenstromsensor 4 Geh use au erhalb des Gefahrenbereichs 5 Durchflussmesser 6 Luftdruckmessger t 7 Druc...

Страница 6: ...und Fehlbestellungen zu ver meiden sind s mtliche Daten des Typenschildes anzugeben Der Ersatzteilkatalog ist verf gbar unter www wilo com 7 Sichere Entsorgung Information zu Sammlung von gebrauchten...

Страница 7: ...rator is in charge of the planning instal lation and operating of the device in compliance with the provisions in force National statutory provisions are to be complied with In collabora tion with the...

Страница 8: ...rt of sensor 3 Delivery rate sensor 4 Box outside of hazardous area 5 Delivery rate controller 6 Air pressure gauge 7 Pressure connection valve 4 1 Scope of delivery Vertical multistage pump with its...

Страница 9: ...f the adjustment follow up time 6 Spare parts All spare parts must be ordered through Wilo customer services In order to avoid any mistakes please specify the rating plate data for orders The spare pa...

Страница 10: ...ce de fonctions importantes de la pompe ou de l installation en consid ration du risque d explosion 2 4 Consignes de s curit pour l utilisateur L utilisateur est responsable de la planification de l i...

Страница 11: ...certifi ATEX se r f rer sa notice 4 Instruction de montage et de mise en service du contr leur de d bit Fig 1 1 Capteur 2 Partie active du capteur 3 Capteur de d bit 4 Coffret hors zone 5 Contr leur...

Страница 12: ...un niveau b1 selon la norme EN 80079 37 V rifier intervalles r gulier son bon fonctionnement fr quence voir la notice du capteur 6 Pi ces de rechange Toutes les pi ces de rechange doivent tre com mand...

Страница 13: ...tivas al riesgo de explosi n 2 4 Instrucciones de seguridad para el operador El operador es responsable de planificar instalar y manejar el aparato de acuerdo con las disposi ciones vigentes En este s...

Страница 14: ...stalaci n y funcionamiento adicionales 4 Manual de instalaci n y puesta en marcha del monitor de caudal Fig 1 1 Sensor 2 Pieza activa del sensor 3 Sensor de caudal 4 Caja fuera del rea peligrosa 5 Mon...

Страница 15: ...ra evitar errores especifique los datos de la placa de caracter sticas en los pedidos Puede consultar el cat logo de repuestos en www wilo com 7 Eliminaci n segura Informaci n sobre la recogida de pro...

Страница 16: ...n confor mit alle disposizioni vigenti Osservare le dis posizioni in vigore presso il rispettivo paese Con l aiuto delle autorit competenti l utente dovr contrassegnare le zone con pericolo di esplosi...

Страница 17: ...ratore di pressione 7 Valvola del raccordo di mandata 4 1 Fornitura Pompa multistadio verticale con il suo motore Monitor di controllo del flusso sensore di portata ATEX 2 raccordi Nastro in Teflon Ma...

Страница 18: ...re specificare i dati riportati sulla targhetta del prodotto da ordinare Il catalogo delle parti di ricambio disponibile su www wilo com 7 Smaltimento sicuro Il corretto smaltimento e riciclaggio di q...

Страница 19: ...dispositivo em con formidade com as normas em vigor Respeitar as normas nacionais Em colabora o com as autoridades competentes o operador deve marcar as reas com risco de explos o e utilizar os materi...

Страница 20: ...rea perigosa 5 Monitor de fluxo 6 Medidor da press o do ar 7 V lvula de liga o da press o 4 1 Equipamento fornecido Bomba multicelular vertical com o seu motor Monitor de fluxo sensor de caudal ATEX 2...

Страница 21: ...fim do tempo de abrandamento para regula o 6 Pe as de substitui o Todas as pe as de substitui o devem ser enco mendadas ao servi o de assist ncia da Wilo Para encomendar sem que surjam enganos especif...

Страница 22: ...22 1 2014 34 1 1 Helix ATEX CE II 2G Ex h IIB T4 Gb 90 C 2 2 1 2 2 2 3 ATEX II 2 2 2 G Ex h IIB T4 135 C Gb EPL G 2 2 b 2 4 2 5 2 6 WILO SE 10 2020...

Страница 23: ...23 3 90 C 15 40 C ATEX 6 8 8 22 5 10 45 12 80 ATEX ATEX 4 Fig 1 1 2 3 4 5 6 7 4 1 ATEX 2 4 2 II 2G T3 T6 90 C 4 3 Fig 1 4 4 4 5 WILO Helix V FIRST V ATEX...

Страница 24: ...24 ATEX 5 5 1 5 2 2 1 MA KM1 KM1 11 13 AT KM1 1 OK 6 Wilo www wilo com 7 1 2 www wilo recycling com WILO SE 10 2020...

Страница 25: ...ILO SE 2 2 IV 1 15 000 10 80 1 2 TOO WILO Central Asia 040704 1 7 727 312 40 10 7 727 312 40 00 220004 7 16 51 017 396 34 53 017 396 34 66 E mail wilo wilo by 010 2011 004 2011 020 2011 RU C DE 08 005...

Страница 26: ...nych funkcji pompy lub instalacji zwi zane z niebezpiece stwem wybu chu 2 4 Zalecenia dla u ytkownik w Obs uguj cy kieruje planowaniem monta em i obs ug urz dzenia zgodnie z obowi zuj cy mi przepisam...

Страница 27: ...e si do instrukcji obs ugi producenta oraz dodatkowej instrukcji monta u i obs ugi 4 Instrukcja monta u i uruchomienia sterownika wydajno ci Fig 1 1 Czujnik 2 Aktywna cz czujnika 3 Czujnik wydajno ci...

Страница 28: ...a dane z tabliczki znamionowej Katalog cz ci zamiennych dost pny jest na stronie www wilo com 7 Bezpieczna utylizacja Informacje dotycz ce zbi rki zu ytych pro dukt w elektrycznych i elektronicznych D...

Страница 29: ...s p slu n mi ady vyzna potenci ln nebez pe n oblasti a bude pou vat odpov daj c mate ri ly V echny informace jsou uvedeny v doku mentu kter se vztahuje k ochran proti explozi 2 5 Bezpe nostn pokyny k...

Страница 30: ...erpac ho v konu ATEX 2 p pojky Teflonov p ska Manu l pro uveden do provozu 4 2 Princip innosti regul toru Na z klad termodynamick ch princip se idlo erpac ho v konu oh eje na teplotu kter je m rn vy...

Страница 31: ...vk ch daje z typov ho t tku Katalog n hradn ch d l je dostupn na str nce www wilo com 7 Bezpe n likvidace Informace o sb ru pou it ch elektrick ch a elektronick ch v robk dnou likvidac a recyklac toh...

Страница 32: ...32 WILO SE 10 2020 1 2014 34 EU 1 1 Helix ATEX II 2G 1 2 IIB T4 90 C 2 2 1 2 2 2 3 2 4 2 5 2 6 3 90 C 15 C 40 C ATEX...

Страница 33: ...33 WILO Helix V FIRST V ATEX M6 8 M8 22 5 M10 45 M12 80 ATEX ATEX 4 Fig 1 1 2 3 4 5 6 7 4 1 ATEX 2 4 2 II 2G T6 T3 90 C 4 3 4 4 4 5...

Страница 34: ...WILO SE 10 2020 34 5 5 1 5 2 2 1 6 Wilo www wilo com 7 1 2 www wilo recycling com 1...

Страница 35: ...35 5 5 1 5 2 LED 1 LED LED 6 Wilo www wilo com 7 1 2 www wilo recycling com LED LED...

Страница 36: ...36 ATEX 22 5 M8 8 M6 80 M12 45 M10 ATEX ATEX 4 Fig 1 1 2 3 4 5 6 7 4 1 ATEX 4 2 T3 II 2G T6 90 Fig 1 4 3 4 4 4 5 ATEX MA KM1 KM1 11 13 AT KM1 WILO SE 10 2020...

Страница 37: ...37 1 2014 34 EU 1 1 Helix ATEX CE II 2G Ex h IIB T4 Gb 90 2 2 1 2 2 2 3 ATEX II 2 2 2 G Ex h IIB T4 135 Gb EPL G 2 2 4 2 5 2 6 3 90 40 15...

Страница 38: ......

Страница 39: ...Organisme notifie Marquage...

Страница 40: ......

Страница 41: ......

Страница 42: ......

Страница 43: ...wilo it Kazakhstan WILO Central Asia 050002 Almaty T 7 727 312 40 10 info wilo kz Korea WILO Pumps Ltd 20 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 52...

Страница 44: ...Pioneering for You WILO SE Wilopark 1 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com Local contact at www wilo com contact...

Отзывы: