10.4. Technical data for RexaLift FIT L2
RexaLift FIT
L2-10
L2-13
L2-16
L2-19
L2-22
Approved field of application
Max. intake/h:
3000 l
3000 l
3000 l
3000 l
3000 l
Max. admissible pressure
in the discharge pipeline:
3 bar
3 bar
3 bar
3 bar
3 bar
Max. delivery head [H]:
10 m
13 m
16 m
19 m
22 m
Max. permitted geodesic
delivery head:
9 m
11.5 m
14.5 m
17 m
19.5 m
Minimum flow rate [Q]:
13 m³/h
13 m³/h
13 m³/h
13 m³/h
13 m³/h
Maximum flow rate [Q]:
35 m³/h
36 m³/h
38 m³/h
40 m³/h
40 m³/h
Fluid temperature [t]:
+3...+40 °C
+3...+40 °C
+3...+40 °C
+3...+40 °C
+3...+40 °C
Max. fluid temperature:
+60 °C for max.
3 min
+60 °C for max.
3 min
+60 °C for max.
3 min
+60 °C for max.
3 min
+60 °C for max.
3 min
Ambient temperature:
+3...+40 °C
+3...+40 °C
+3...+40 °C
+3...+40 °C
+3...+40 °C
Max. solid grain size:
40 mm
40 mm
40 mm
40 mm
40 mm
Motor data
Mains connection [U/f]:
3~400 V/50 Hz
3~400 V/50 Hz
3~400 V/50 Hz
3~400 V/50 Hz
3~400 V/50 Hz
Type of connection:
CEE plug
CEE plug
CEE plug
CEE plug
CEE plug
Power consumption [P
1
]:
2.3 kW
2.6 kW
3.3 kW
3.6 kW
4.2 kW
Rated power [P
2
]:
1.75 kW
2.1 kW
2.6 kW
3.0 kW
3.5 kW
Rated current [I
N
]:
3.7 A
1)
4.5 A
1)
5.4 A
1)
6.3 A
1)
7 A
1)
Speed [n]:
2870 rpm
2880 rpm
2850 rpm
2920 rpm
2890 rpm
Activation type [AT]:
direct
direct
direct
direct
direct
Protection class unit:
IP 67 (2 mWs, 7 D) IP 67 (2 mWs, 7 D) IP 67 (2 mWs, 7 D) IP 67 (2 mWs, 7 D) IP 67 (2 mWs, 7 D)
Switchgear protection
class:
IP 54
IP 54
IP 54
IP 54
IP 54
Max. switching opera
-
tions/h:
60
2)
60
2)
60
2)
60
2)
60
2)
Operating mode:
S3 10 %/120 s
S3 10 %/120 s
S3 10 %/120 s
S3 10 %/120 s
S3 10 %/120 s
Connections
Pressure connection:
DN 80
DN 80
DN 80
DN 80
DN 80
Inlet connection:
DN 50, DN 100,
DN 150
DN 50, DN 100,
DN 150
DN 50, DN 100,
DN 150
DN 50, DN 100,
DN 150
DN 50, DN 100,
DN 150
Ventilation connection:
DN 70
DN 70
DN 70
DN 70
DN 70
Dimensions and weights
Gross volume:
140 l
140 l
140 l
140 l
140 l
Max. useable volume:
50 l
50 l
50 l
50 l
50 l
Switch-on level (for in
-
stallation level):
185 mm
185 mm
185 mm
185 mm
185 mm
Dimensions
(WxHxD):
830x590x755
mm
830x675x755
mm
830x675x755
mm
830x675x755
mm
830x675x755
mm
Diagonal dimension:
1060 mm
1060 mm
1060 mm
1060 mm
1060 mm
Sound-pressure level:
< 70 dB(A)
3)
< 70 dB(A)
3)
< 70 dB(A)
3)
< 70 dB(A)
3)
< 70 dB(A)
3)
Weight:
65 kg
69 kg
69 kg
81 kg
81 kg
•
1)
Rated current per pump; the value doubles during emergency operation when the pumps are in parallel connection
•
2)
30 switches per pump in alternating operation
•
3)
The sound-pressure level depends on the duty point and may vary. Incorrect installation or impermissible opera
-
tion can increase the sound-pressure level.
Содержание RexaLift FIT L Series
Страница 4: ...Fig 7 Fig 6 Fig 5 10 20 mm 1 1 1 1 1 3 2 3 3 4 4 4 5 5 1 2 3 4 1 2 1 2...
Страница 5: ...Fig 8 Fig 9 1 3 2 min 25 mm...
Страница 6: ......
Страница 26: ......
Страница 27: ......