46 

WILO SE 01/2014 Ed.05 DIN A4

English APPENDIX

10.3. Technical data for RexaLift FIT L1

RexaLift FIT

L1-10

L1-13

L1-16

L1-19

L1-22

Approved field of application

Max. intake/h:

1050 l

1050 l

1050 l

1050 l

1050 l

Max. admissible pressure 

in the discharge pipeline:

3 bar

3 bar

3 bar

3 bar

3 bar

Max. delivery head [H]:

10 m

13 m

16 m

19 m

22 m

Max. permitted geodesic 

delivery head:

9 m

11.5 m

14.5 m

17 m

19.5 m

Minimum flow rate [Q]:

13 m³/h

13 m³/h

13 m³/h

13 m³/h

13 m³/h

Maximum flow rate [Q]:

35 m³/h

36 m³/h

38 m³/h

40 m³/h

40 m³/h

Fluid temperature [t]:

+3...+40 °C

+3...+40 °C

+3...+40 °C

+3...+40 °C

+3...+40 °C

Max. fluid temperature:

+60 °C for max. 
3 min

+60 °C for max. 
3 min

+60 °C for max. 
3 min

+60 °C for max. 
3 min

+60 °C for max. 
3 min

Ambient temperature:

+3...+40 °C

+3...+40 °C

+3...+40 °C

+3...+40 °C

+3...+40 °C

Max. solid grain size:

40 mm

40 mm

40 mm

40 mm

40 mm

Motor data

Mains connection [U/f]:

3~400 V/50 Hz

3~400 V/50 Hz

3~400 V/50 Hz

3~400 V/50 Hz

3~400 V/50 Hz

Type of connection:

CEE plug

CEE plug

CEE plug

CEE plug

CEE plug

Power consumption [P

1

]:

2.3 kW

2.6 kW

3.3 kW

3.6 kW

4.2 kW

Rated power [P

2

]:

1.75 kW

2.1 kW

2.6 kW

3.0 kW

3.5 kW

Rated current [I

N

]:

3.7 A

4.5 A

5.4 A

6.3 A

7 A

Speed [n]:

2870 rpm

2880 rpm

2850 rpm

2920 rpm

2890 rpm

Activation type [AT]:

direct

direct

direct

direct

direct

Protection class unit:

IP 67 (2 mWs/7 d) IP 67 (2 mWs/7 d) IP 67 (2 mWs/7 d) IP 67 (2 mWs/7 d) IP 67 (2 mWs/7 d)

Switchgear protection 
class:

IP 54

IP 54

IP 54

IP 54

IP 54

Max. switching opera

-

tions/h:

30

30

30

30

30

Operating mode:

S3 10 %/120 s

S3 10 %/120 s

S3 10 %/120 s

S3 10 %/120 s

S3 10 %/120 s

Connections

Pressure connection:

DN 80

DN 80

DN 80

DN 80

DN 80

Inlet connection:

DN 50, DN 100, 
DN 150

DN 50, DN 100, 
DN 150

DN 50, DN 100, 
DN 150

DN 50, DN 100, 
DN 150

DN 50, DN 100, 
DN 150

Ventilation connection:

DN 70

DN 70

DN 70

DN 70

DN 70

Dimensions and weights

Gross volume:

115 l

115 l

115 l

115 l

115 l

Max. useable volume:

35 l

35 l

35 l

35 l

35 l

Switch-on level (for in

-

stallation level):

175 mm

175 mm

175 mm

175 mm

175 mm

Dimensions 

(WxHxD):

630x590x770 

mm

630x675x770 

mm

630x675x770 

mm

630x675x770 

mm

630x675x770 

mm

Diagonal dimension:

945 mm

945 mm

945 mm

945 mm

945 mm

Sound-pressure level:

< 70 dB(A) 

3)

< 70 dB(A) 

3)

< 70 dB(A) 

3)

< 70 dB(A) 

3)

< 70 dB(A) 

3)

Weight:

45 kg

47 kg

47 kg

53 kg

53 kg

• 

3)

 The sound-pressure level depends on the duty point and may vary. Incorrect installation or impermissible opera

-

tion can increase the sound-pressure level.

Содержание RexaLift FIT L Series

Страница 1: ...ice de montage et de mise en service es Instrucciones de instalaci n y funcionamiento it Istruzioni di montaggio uso e manutenzione pt Manual de Instala o e funcionamento tr Montaj ve kullanma k lavuz...

Страница 2: ...Fig 2 RexaLift FIT L1 Fig 2 RexaLift FIT L2 Fig 2 Fig 1 RexaLift FIT L1 Fig 1 RexaLift FIT L2 7 1 3 6 5 6 8 4 2 7 1 3 5 6 8 4 4 2 3 2 1 1...

Страница 3: ...aLift FIT L2 Fig 4 RexaLift FIT L1 305 85 185 15 185 15 250 180 305 85 185 15 250 180 152 253 305 85 174 15 250 180 250 180 235 235 85 305 15 15 15 164 305 85 243 152 180 250 305 85 15 164 250 180 1 3...

Страница 4: ...Fig 7 Fig 6 Fig 5 10 20 mm 1 1 1 1 1 3 2 3 3 4 4 4 5 5 1 2 3 4 1 2 1 2...

Страница 5: ...Fig 8 Fig 9 1 3 2 min 25 mm...

Страница 6: ......

Страница 7: ...es optionally available 35 4 Transport and storage 35 4 1 Delivery 35 4 2 Transport 35 4 3 Storage 35 4 4 Return delivery 36 5 Installation 36 5 1 General 36 5 2 Installation methods 36 5 3 Installati...

Страница 8: ...ontains the general information on the warranty Contractual agreements have the highest priority and are not superseded by the information in this section The manufacturer is obliged to correct any de...

Страница 9: ...2 General safety The lifting unit must be switched off before any work is performed installation dismantling maintenance installation The lifting unit must be disconnected from the electricity network...

Страница 10: ...ing operation The monitoring equipment is connected in the switchgear at the factory Personnel must be informed about the installed systems and how they work CAUTION The lifting unit is not allowed to...

Страница 11: ...to EN 12056 1 Explosive fluids Potable water The system must be installed in accordance with the general rules as detailed in EN 12056 and DIN 1986 100 The intended use includes complying with these...

Страница 12: ...itchgear and CEE plug including phase inverter Double pump system with switchgear and CEE plug including phase inverter 3 3 Operating principle The sewage that arrives is channelled into the collectio...

Страница 13: ...this date cannot be recognised Damage to parts must be noted on the delivery or freight documentation 4 2 Transport Only the appropriate and approved fastening de vices transportation and lifting gear...

Страница 14: ...nical sewage systems observe the pertinent local regulations and directives for sewage technology such as those of the German Association for Water Wastewater and Waste In particular pressure surges w...

Страница 15: ...directly at the edge of the sump Lack of care and or incorrect choice of cloth ing can result in falling There is a risk of fatal injury Take all necessary safety precautions to prevent this Rough sol...

Страница 16: ...oint A gate valve must be installed directly after the pressure connection a non return valve with a ventilation device is integrated in the pressure connection The pressure pipe is then mounted on th...

Страница 17: ...bsolutely leak tight A max tightening torque of 5 Nm is permitted when using pipe clamps Fig 6 Installing the DN 70 bleed line 1 DN 50 70 combined connection 2 Saw 1 Open the DN 50 70 combined connect...

Страница 18: ...red must be rated accord ing to the starting current Refer to the rating plate for the starting current Only slow blow fuses or K type circuit breakers are allowed to be used as the back up fuse The m...

Страница 19: ...he external alarm signal optional Assembling the diaphragm hand pump for emer gency draining System completely cleaned especially of solid matter 6 1 2 Checking the system Complete the following tasks...

Страница 20: ...l an addi tional non return valve with a counterweight The pump run time should be determined as follows If a slurping noise can be heard before the pump is switched off pumping a water air mixture bu...

Страница 21: ...observe the operating instructions for the diaphragm hand pump 7 Decommissioning disposal All work must be carried out with the greatest care Proper protective clothing is to be worn When working in s...

Страница 22: ...office or the supplier from whom you obtained the product 8 Maintenance and repair For reasons of safety and thus to guarantee cor rect function of the lifting unit it must always be maintained by Wil...

Страница 23: ...tches back on automatically after the winding has cooled down Frequent switch off by the winding temperature monitoring Wilo customer service 16 Pump ventilation clogged Clean the pump ventilation lin...

Страница 24: ...kW Rated current IN 3 7 A 4 5 A 5 4 A 6 3 A 7 A Speed n 2870 rpm 2880 rpm 2850 rpm 2920 rpm 2890 rpm Activation type AT direct direct direct direct direct Protection class unit IP 67 2 mWs 7 d IP 67...

Страница 25: ...880 rpm 2850 rpm 2920 rpm 2890 rpm Activation type AT direct direct direct direct direct Protection class unit IP 67 2 mWs 7 D IP 67 2 mWs 7 D IP 67 2 mWs 7 D IP 67 2 mWs 7 D IP 67 2 mWs 7 D Switchgea...

Страница 26: ......

Страница 27: ......

Страница 28: ...Pioneering for You WILO SE Nortkirchenstra e 100 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: