44

 

WILO SE 01/2014 Ed.05 DIN A4

English

 

MAINTENANCE AND REPAIR

4.  Disconnect the connection between the inlet 

pipe and the inlet seal, and pull the inlet pipe out 
of the seal.

5.  Disconnect the connection between the gate 

valve and the pressure connection.

6. 

Disconnect the connection between the ventila-
tion pipe and the ventilation connection, and pull 
the pipe up off the connecting piece.

7. 

Also remove the DN 50 inlet, if there is one.

8. 

Then disconnect the diaphragm hand pump from 

the lifting unit if it is installed.

9. 

Once all connections have been disconnected, 

release the anchoring points of the lifting unit in 

the floor

10.  Now the lifting unit can be pulled carefully out of 

the pipework.

11. 

Flush through the lifting unit with clean water and 

disinfect it

12. 

Firmly close all connecting pipes, clean and disin

-

fect them.

13.  Clean the operating space and disinfect it if 

necessary.

7.3.  Return delivery / storage

Lifting units that are sent back to the factory 

must be cleaned to remove impurities and, if they 

have been used with fluids that are harmful to 

health, they must also be decontaminated.

For shipping, the parts must be packed in tear-
proof plastic bags of sufficient size in such a 

manner that they are tightly sealed and leak-

proof. Furthermore, the packaging must protect 

the lifting unit from damage during transporta-
tion. If you have any questions, please contact 
the manufacturer!

Please also refer to the "Transport and storage" 

section for the return delivery and putting into 

storage!

7.4.  Disposal

7.4.1.  Protective clothing

The protective clothing and cleaning cloths must 
be disposed of acc. to waste code TA 524 02 and 
EC Directive 91/689/EEC, or acc. to local direc

-

tives.

7.4.2.  Product

Proper disposal of this product avoids damage to 
the environment and risks to personal health.

• Use the services of public or private waste dis-

posal companies, or consult them for the disposal 
of the product or parts thereof.

• 

For more information on proper disposal, please 
contact your local council or waste disposal office 

or the supplier from whom you obtained the 
product.

8.  Maintenance and repair

For reasons of safety, and thus to guarantee cor

-

rect function of the lifting unit, it must always be 
maintained by Wilo customer service. 

The maintenance intervals for lifting units are 
determined by EN 12056-4:

• ¼ year in the case of commercial companies
• ½ year for units in multi-family houses
• 1 year for units in single-family houses

A log must be kept of all maintenance and repair 
work, which must be signed by the service em-
ployee and the end-user.

NOTE

 

We recommend concluding a maintenance 
contract for regular maintenance work. Please 
contact Wilo customer service for more infor-
mation about this.

9.  Troubleshooting and possible solutions

In order to prevent damage or serious injury when 
repairing malfunctions on the lifting unit, the 
following points must always be observed:

• 

Only repair a malfunction if qualified personnel 

are available for this work, i.e. the individual tasks 

must be carried out by trained specialists. For 
example, electrical work must be performed by an 

electrician.

• Always secure the lifting unit to prevent it re-

starting inadvertently, by disconnecting it from 

the electrical mains. Take appropriate precau

-

tions.

• Also comply with the installation and operating 

instructions provided with the accessories used!

• 

Unsanctioned modifications to the lifting unit are 

made at the operator's own risk and release the 
manufacturer from any warranty obligations!

9.1.  Overview of possible malfunctions

Fault

Identifier for cause and 

remedy

Lifting unit does not pump

1, 3, 5, 6, 7, 8, 9, 10, 11, 12, 
15, 16, 17

Volume flow too low

1, 2, 3, 4, 5, 7, 8, 11, 12, 13

Current consumption too 

high

1, 2, 3, 4, 5, 7, 13

Delivery head too small

1, 2, 3, 4, 5, 8, 11, 12, 13, 16

Lifting unit runs roughly / 

loud noise

1, 2, 3, 9, 12, 13, 14, 16

9.2.  Overview of possible causes and their remedies

1.  Inlet or impeller clogged

• Remove deposits from the inlet, reservoir and/

or pump ⇒ Wilo customer service

2.  Incorrect direction of rotation

• 

Exchange 2 phases of the current feed ⇒ Wilo 

customer service

3. 

Wear of inner parts (e.g. impeller, bearing)

• 

Renew worn parts ⇒ Wilo customer service

4. 

Operating voltage too low

• 

Have the mains connection checked ⇒ elec

-

trician

5.  Running on two phases

Содержание RexaLift FIT L Series

Страница 1: ...ice de montage et de mise en service es Instrucciones de instalaci n y funcionamiento it Istruzioni di montaggio uso e manutenzione pt Manual de Instala o e funcionamento tr Montaj ve kullanma k lavuz...

Страница 2: ...Fig 2 RexaLift FIT L1 Fig 2 RexaLift FIT L2 Fig 2 Fig 1 RexaLift FIT L1 Fig 1 RexaLift FIT L2 7 1 3 6 5 6 8 4 2 7 1 3 5 6 8 4 4 2 3 2 1 1...

Страница 3: ...aLift FIT L2 Fig 4 RexaLift FIT L1 305 85 185 15 185 15 250 180 305 85 185 15 250 180 152 253 305 85 174 15 250 180 250 180 235 235 85 305 15 15 15 164 305 85 243 152 180 250 305 85 15 164 250 180 1 3...

Страница 4: ...Fig 7 Fig 6 Fig 5 10 20 mm 1 1 1 1 1 3 2 3 3 4 4 4 5 5 1 2 3 4 1 2 1 2...

Страница 5: ...Fig 8 Fig 9 1 3 2 min 25 mm...

Страница 6: ......

Страница 7: ...es optionally available 35 4 Transport and storage 35 4 1 Delivery 35 4 2 Transport 35 4 3 Storage 35 4 4 Return delivery 36 5 Installation 36 5 1 General 36 5 2 Installation methods 36 5 3 Installati...

Страница 8: ...ontains the general information on the warranty Contractual agreements have the highest priority and are not superseded by the information in this section The manufacturer is obliged to correct any de...

Страница 9: ...2 General safety The lifting unit must be switched off before any work is performed installation dismantling maintenance installation The lifting unit must be disconnected from the electricity network...

Страница 10: ...ing operation The monitoring equipment is connected in the switchgear at the factory Personnel must be informed about the installed systems and how they work CAUTION The lifting unit is not allowed to...

Страница 11: ...to EN 12056 1 Explosive fluids Potable water The system must be installed in accordance with the general rules as detailed in EN 12056 and DIN 1986 100 The intended use includes complying with these...

Страница 12: ...itchgear and CEE plug including phase inverter Double pump system with switchgear and CEE plug including phase inverter 3 3 Operating principle The sewage that arrives is channelled into the collectio...

Страница 13: ...this date cannot be recognised Damage to parts must be noted on the delivery or freight documentation 4 2 Transport Only the appropriate and approved fastening de vices transportation and lifting gear...

Страница 14: ...nical sewage systems observe the pertinent local regulations and directives for sewage technology such as those of the German Association for Water Wastewater and Waste In particular pressure surges w...

Страница 15: ...directly at the edge of the sump Lack of care and or incorrect choice of cloth ing can result in falling There is a risk of fatal injury Take all necessary safety precautions to prevent this Rough sol...

Страница 16: ...oint A gate valve must be installed directly after the pressure connection a non return valve with a ventilation device is integrated in the pressure connection The pressure pipe is then mounted on th...

Страница 17: ...bsolutely leak tight A max tightening torque of 5 Nm is permitted when using pipe clamps Fig 6 Installing the DN 70 bleed line 1 DN 50 70 combined connection 2 Saw 1 Open the DN 50 70 combined connect...

Страница 18: ...red must be rated accord ing to the starting current Refer to the rating plate for the starting current Only slow blow fuses or K type circuit breakers are allowed to be used as the back up fuse The m...

Страница 19: ...he external alarm signal optional Assembling the diaphragm hand pump for emer gency draining System completely cleaned especially of solid matter 6 1 2 Checking the system Complete the following tasks...

Страница 20: ...l an addi tional non return valve with a counterweight The pump run time should be determined as follows If a slurping noise can be heard before the pump is switched off pumping a water air mixture bu...

Страница 21: ...observe the operating instructions for the diaphragm hand pump 7 Decommissioning disposal All work must be carried out with the greatest care Proper protective clothing is to be worn When working in s...

Страница 22: ...office or the supplier from whom you obtained the product 8 Maintenance and repair For reasons of safety and thus to guarantee cor rect function of the lifting unit it must always be maintained by Wil...

Страница 23: ...tches back on automatically after the winding has cooled down Frequent switch off by the winding temperature monitoring Wilo customer service 16 Pump ventilation clogged Clean the pump ventilation lin...

Страница 24: ...kW Rated current IN 3 7 A 4 5 A 5 4 A 6 3 A 7 A Speed n 2870 rpm 2880 rpm 2850 rpm 2920 rpm 2890 rpm Activation type AT direct direct direct direct direct Protection class unit IP 67 2 mWs 7 d IP 67...

Страница 25: ...880 rpm 2850 rpm 2920 rpm 2890 rpm Activation type AT direct direct direct direct direct Protection class unit IP 67 2 mWs 7 D IP 67 2 mWs 7 D IP 67 2 mWs 7 D IP 67 2 mWs 7 D IP 67 2 mWs 7 D Switchgea...

Страница 26: ......

Страница 27: ......

Страница 28: ...Pioneering for You WILO SE Nortkirchenstra e 100 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: