Wilo Control MS-L  2x4kW Series Скачать руководство пользователя страница 7

28

 

WILO SE 04-2015 V05 DIN A4

English INTRODUCTION

1.  Introduction

1.1.  About this document

The language of the original operating instruc-

tions is German. All other languages of these 

instructions are translations of the original oper-

ating instructions.

This manual is divided into individual sections, 

which are listed in the table of contents. Each 

section has a heading which clearly describes its 

content.

A copy of the EC declaration of conformity is 

a component of these operating instructions.

If a technical modification is made on the designs 

named there without our agreement, this decla-

ration loses its validity.

1.2. 

Personnel qualifications

All personnel who work on or with the switchgear 

must be qualified for such work; electrical work, 

for example, may only be carried out by a qualified 

electrician. All personnel must be of legal age.

Operating and maintenance personnel must also 

observe national accident prevention regulations.

It must be ensured that personnel have read and 

understood the instructions in this operating and 

maintenance handbook; if necessary, this manual 

must be ordered from the manufacturer in the 

required language.

This switchgear is not intended for use by persons 

(including children) with reduced physical, senso-

ry or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervi-

sion or instruction concerning use of the switch-

gear by a person responsible for their safety.

Children should be supervised to ensure that they 

do not play with the switchgear.

1.3.  Copyright

This operating and maintenance manual has been 

copyrighted by the manufacturer. The operating 

and maintenance manual is intended for use by 

installation, operating and maintenance person-

nel. It contains technical regulations and drawings 

which may not be reproduced or distributed, 

either in whole or in part, used for purposes of 

competition or shared with third parties. Illustra-

tions may differ from the original and serve only 

as example illustrations of switchgears.

1.4. 

Rights of modification

The manufacturer reserves the right to make 

technical modifications to systems or compo

-

nents. This operation and maintenance manual 

refers to the switchgear indicated on the title 

page.

1.5.  Warranty

In general, the specifications in the current "gen

-

eral terms and conditions" apply for the warranty. 

You can find these here:

 

www.wilo.com/legal

Any deviations must be contractually agreed and 

shall then be given priority.

1.5.1.  General

The manufacturer is obliged to correct any de-

fects found in the switchgears it sells, provided 

that the one or more of the following is the case:

• The defects are caused by the materials used 

or the way the product was manufactured or 

designed.

• The defects were reported in writing to the man-

ufacturer within the agreed warranty period.

• The switchgear was used only as prescribed.

1.5.2.  Warranty period

The duration of the warranty period is stipulated 

in the "general terms and conditions".

Any deviations must be contractually agreed.

1.5.3. 

Spare parts, attachments and modifications

Only genuine spare parts from the manufacturer 

may be used for repairs, replacements, attach-

ments and modifications. Unauthorised add-ons 

and modifications or the use of non-original spare 

parts can seriously damage the switchgear and/or 

injure personnel.

1.5.4.  Maintenance

The prescribed maintenance and inspection 

work should be carried out regularly. This work 

may only be carried out by qualified, trained and 

authorised personnel.

1.5.5.  Damage to the product

Damage and malfunctions that endanger safety 

must be eliminated immediately by trained per-

sonnel. The switchgear may only be operated if it 

is in proper working order.

In general, repairs should only be carried out by 

Wilo customer service.

1.5.6.  Disclaimer

No liability will be assumed for damage to the 

switchgear if any of the following is the case:

• The manufacturer deems that information pro-

vided by the operator or customer is insufficient 

or incorrect

• Non-compliance with safety instructions and 

working instructions as specified in this operating 

and maintenance manual

• Improper use

• Incorrect storage and transport

• Improper assembly/dismantling

• 

Insufficient maintenance

• Incorrect repairs

• Inadequate construction site or construction work

• 

Chemical, electrochemical and electrical influ

-

ences

• Wear

This means the manufacturer’s liability excludes 

all liability for personal injury, material damage or 

financial losses.

2.  Safety

This section lists all the generally applicable 

safety instructions and technical information. 

Содержание Control MS-L 2x4kW Series

Страница 1: ...e manutenzione pt Manual de Instala o e funcionamento nl Inbouw en bedieningsvoorschriften da Monterings og driftsvejledning sv Monterings och sk tselanvisning fi Asennus ja k ytt ohje el hr Upute za...

Страница 2: ...Fig 1 1 2 3...

Страница 3: ...SSM Alarm GL WSK P2 WSK P1 SL 10 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 HW T1 1 3 5 13 A1 2 4 6 14 A2 T2 T3 L1 L2 L3 NO L1 L2 L3 N WSK M 3 WSK M 1 T1 1 3 5 13 A1 2 4 6 14 A2 T2 T3 L1 L2 L3 NO ON DIP 1 2...

Страница 4: ...50Hz U brown yellow green pink grey brown black grey blue V W white P1 P2 ON OFF ON NW 16 black brown black grey blue brown 30 15 0 Seconds ON 100 K DIP 1 2 3 4 5 6 7 SSM Alarm GL WSK P2 WSK P1 SL 10...

Страница 5: ...N 100 K DIP 1 2 3 4 5 6 7 SSM Alarm GL WSK P2 WSK P1 SL 10 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 HW T1 1 3 5 13 A1 2 4 6 14 A2 T2 T3 L1 L2 L3 NO L1 L2 L3 N WSK M 3 WSK M 1 T1 1 3 5 13 A1 2 4 6 14 A2 T2...

Страница 6: ...ry 32 5 Installation 32 5 1 General 32 5 2 Types of installation 32 5 3 Installation 32 5 4 Electrical connection 33 6 Operation and function 36 6 1 Controls 36 6 2 Button lock 37 7 Commissioning 37 7...

Страница 7: ...refers to the switchgear indicated on the title page 1 5 Warranty In general the specifications in the current gen eral terms and conditions apply for the warranty You can find these here www wilo co...

Страница 8: ...les and or insulation the switchgear must be shut down immediately by the operator Tools and other objects should be kept in their designated places so that they can be found quickly The switchgear ma...

Страница 9: ...with buttons 2 LED indicators The switchgear comprises the following main components Main switch for switching the switchgear on off NOTE The S version has no main switch A plug is pre assembled inste...

Страница 10: ...ns connection Installation and operating instructions Variant S Switchgear with connected cable and plug 1 230 V Shockproof plug 3 400 V CEE phase inverter plug with phase inverter Installation and op...

Страница 11: ...must be clean dry and free of vibrations Avoid exposing the switchgear to direct sunlight The customer must provide the power supply cables These must be of sufficient length so that connection to the...

Страница 12: ...by an electrician authorised by the local energy supply company Observe the installation and operating in structions for the connected pump and signal transmitters The mains connection current and vo...

Страница 13: ...ct ed to the earth terminal NOTE With the S version the pump is connected at terminals 2 T1 L 4 T2 N Pump connection 3 400 V Terminals 2 T1 U 4 T2 V 6 T3 W The protective ground conductor PE is con ne...

Страница 14: ...inals 11 12 and 13 of the termi nal strip DANGER due to electrical voltage An external voltage is applied at the terminals for this function This is also present at the terminals when the main switch...

Страница 15: ...ill be emitted independent of the electricity network on power failure An audible constant tone will be emitted as an alarm 1 Place the rechargeable battery in the holder Pay attention to the correct...

Страница 16: ...fault signal relay deactivated during an alarm signal with the Buzzer OFF Reset button Faults cannot be acknowledged nor can the control be released 7 Commissioning POTENTIALLY fatal danger due to ele...

Страница 17: ...direction of rotation and set Observe the wire designations on the wiring diagram when connecting the switchgear and the connected pumps 7 4 1 Checking the direction of rotation The rotation control o...

Страница 18: ...rdingly Ambient operating temperature 30 60 C Air humidity 40 50 Prevent formation of condensate BEWARE of moisture Ingress of moisture will result in damage to the switchgear During standstill time p...

Страница 19: ...ectrician or Wilo Customer Service 9 3 Repair work Prior to repair work the switchgear must be switched off as described under Final shutdown and all power supply cables dismantled Repair work must be...

Страница 20: ...ooting If the points listed here do not rectify the fault contact Wilo Customer Service They can help you as follows Telephone and or written support from Wilo Customer Service On site support from Wi...

Страница 21: ...ung folgenden einschl gigen Bestimmungen entspricht in its delivered state complies with the following relevant provisions est conforme aux dispositions suivants dont il rel ve Niederspannungsrichtlin...

Страница 22: ...Pioneering for You WILO SE Nortkirchenstra e 100 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: