![Wilden PRO-FLO P8 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/wilden/pro-flo-p8/pro-flo-p8_engineering-operation-and-maintenance-manual_980887023.webp)
WIL-10187-E-05
23
P8 Clamped Plastic
Carefully prepare sealing surfaces by removing all debris and foreign matter from diaphragm bead and all mating surfaces. If necessary,
smooth or deburr all sealing surfaces. Mating surfaces must be properly aligned in order to ensure positive sealing characteristics.
Step 1
Step 2
Step 3
Gently remove the adhesive covering from
the back of the PTFE tape. Ensure that
the adhesive strip remains attached to the
PTFE tape.
Starting at any point, place the PTFE tape
in the center of the diaphragm bead
groove on the liquid chamber and press
lightly on the tape to ensure that the
adhesive holds in place during assembly.
Do not stretch the tape during placement
in the center of diaphragm bead groove.
The end of the tape should overlap
approximately 13 mm (1/2"). Proceed to
install the PTFE tape on the remaining
diaphragm.
GASKET KIT INSTALLATION (08-9502-99)
Содержание PRO-FLO P8